Alternative coulometric signal readout based on a solid-contact ion-selective electrode for detection of nitrate
Hemin Wang1, Baiqing Yuan2, Tanji Yin3
1School of Chemistry and Materials Science, Ludong University, Yantai, 264025, Shandong, PR China; Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research (YIC), Chinese Academy of Sciences (CAS), Shandong Provincial Key Laboratory of Coastal Environmental Processes, YICCAS, Yantai, Shandong, 264003, PR China.
Abstract:
Traditional potentiometric NO3--selective electrodes suffer from a fundamental limitation of the Nernst slope (59.1 mV/dec at 25 °C) due to the relationship between the potential and the logarithmic of ionic activity. Herein, a coulometric signal readout is proposed instead of the potentiometric response for detection of NO3- based on an ordered mesoporous carbon (OMC)-based solid-contact ion-selective electrode (ISE). The mechanism for obtaining the coulometric signal is based on the electrical double layer capacitance of OMC compensating the potential change at the ion-selective membrane/solution interface during the measurements under the control of a constant applied potential. Under the optimized conditions, the coulometric signal for the OMC-based solid-contact NO3--ISE shows two linear responses in the activity range of 1.0 × 10-6-8.0 × 10-6 M and 8.0 × 10-6-8.0 × 10-4 M, and the detection limit is 4.0 × 10-7 M (3σ/s). The proposed coulometric response also shows excellent reproducibility and stability in the presence of O2 and CO2 and light on/off. Additionally, the coulometric response shows acceptable and reliable results for detection of NO3- in mineral water as compared to the traditional potentiometric response and the ion chromatography. This work provides a promising alternative signal readout for detection of ions by using solid-contact ion-selective electrodes.
More Related Videos
Related Concept Videos
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Potentiometry: Membrane Electrodes
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Controlled-Current Coulometry: Overview
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...