Related Experiment Video
Updated: Dec 9, 2025

Ultrasonic Welding of Thermoplastic Composite Coupons for Mechanical Characterization of Welded Joints through Single Lap Shear Testing
Published on: February 11, 2016
Pulse-heating infrared thermography inspection of bonding defects on carbon fiber reinforced polymer composites
Bo Wen1, Zhenwei Zhou1, Bin Zeng2
1Southeast University, Key Laboratory of Concrete and Prestressed Concrete Structure of Ministry of Education, Nanjing, P. R. China.
Abstract:
Non-destructive analysis of fiber reinforced polymer (FRP) composites is important for confirming the long-term safety and durability of concrete structures. In this study, a pulse-heating infrared thermography technique was used to detect and characterize bonding defects of externally bonded carbon fiber reinforced polymers (CFRP) on concrete surface structures. The CFRP composite contains various bonding defects of three different sizes located at five different depths. Sequential thermal images were obtained to describe the temperature contrast and shapes of the bonding defects. Through analysis of the maximum temperature response, we investigated the effects of defect size and depth on the defect temperature response. The relationship between the defect depth and maximum temperature response was used to quantitatively estimate the defect depth. In addition, finite element simulations were performed on the CFRP composites with bonding defects to investigate the temperature response of various defects, which showed good agreement with the experimental results. This confirms the effectiveness of the infrared thermography method to detect and characterize bonding defects of FRP composites bonded on concrete structures.