Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Noninvasive Cardiac Output Monitoring in Newborn with Hypoplastic Left Heart Syndrome
Italo Francesco Gatelli1, Ottavio Vitelli2, Gaia Chiesa1
1Neonatal Intensive Care Unit, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy.
Objective:
This study aimed to describe the first two cases of electrical cardiometry applied to newborn with hypoplastic left heart syndrome for hemodynamical assessment in the first days of life before surgical correction and see if this can help decision making process in these patients.
Study Design:
We describe two case series of two full-term newborn with hypoplastic left heart syndrome in the Neonatal Intensive Care Unit, ASST Grande Ospedale Metropolitano Niguarda, between December 2019 and January 2020.
Results:
Case 1 was persistently hemodynamically stable with prostaglandin E1 infusion at 0.01 mcg/kg/min, showing good capillary refill time, good diuresis, no difference between pre- and postductal values of oxygen saturation or blood pressure. Electrical cardiometry monitoring constantly showed cardiac output values higher than 300 mL/kg/min. Case 2 showed poor clinical condition needing prostaglandin E1 infusion up to 0.05 mcg/kg/min, intubation and septostomy associated with low cardiac output around 190 mL/kg/min. Once cardiac output has begun to rise and reached values constantly over 300 mL/kg/min, clinical condition improved with amelioration in oxygen saturation, diuresis, blood pressure, and blood gas analysis values. She was then extubated and finally clinically stable until surgery with minimal infusion of prostaglandin E1 at 0.01 mcg/kg/min.
Conclusion:
This case highlights how hemodynamic information provided by electrical cardiometry can be used to supplement the combined data from all monitors and the clinical situation to guide therapy in these newborns waiting surgery.
Key Points:
· This is the first report of electrical cardiometry (EC) use in newborn with hypoplastic left heart syndrome (HLHS).. · In HLHS patients, it is impossible to measure cardiac output without being invasive.. · EC helps in guiding therapy in HLHS patients in a noninvasive way..
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...