Validation of an Instrument for Real-Time Assessment of Neonatal Intubation Skills: A Randomized Controlled
Lindie J M K Kuijpers1, Mathijs Binkhorst1, Nicole K Yamada2
1Department of Neonatology, Radboud University Medical Center Amalia Children's Hospital, Nijmegen, The Netherlands.
Objective:
This study aimed to evaluate the construct validity and reliability of real-time assessment of a previously developed neonatal intubation scoring instrument (NISI).
Study Design:
We performed a randomized controlled simulation study at a simulation-based research and training facility. Twenty-four clinicians experienced in neonatal intubation ("experts") and 11 medical students ("novices") performed two identical elective intubations on a neonatal patient simulator. Subjects were randomly assigned to either the intervention group, receiving predefined feedback between the two intubations, or the control group, receiving no feedback. Using the previously developed NISI, all intubations were assessed, both in real time and remotely on video. Construct validity was evaluated by (1) comparing the intubation performances, expressed as percentage scores, with and without feedback, and (2) correlating the intubation performances with the subjects' level of experience. The intrarater reliability, expressed as intraclass correlation coefficient (ICC), of real-time assessment compared with video-based assessment was determined.
Results:
The intervention group contained 18 subjects, the control group 17. Background characteristics and baseline intubation scores were comparable in both groups. The median (IQR) change in percentage scores between the first and second intubation was significantly different between the intervention and control group (11.6% [4.7-22.8%] vs. 1.4% [0.0-5.7%], respectively; p = 0.013). The 95% CI for this 10.2% difference was 2.2 to 21.4%. The subjects' experience level correlated significantly with their percentage scores (Spearman's R = 0.70; p <0.01). ICC's were 0.95 (95% CI: 0.89-0.97) and 0.94 (95% CI: 0.89-0.97) for the first and second intubation, respectively.
Conclusion:
Our NISI has construct validity and is reliable for real-time assessment.
Key Points:
· Our neonatal intubation scoring instrument has construct validity.. · Our instrument can be reliably employed to assess neonatal intubation skills directly in real time.. · It is suitable for formative assessment, i.e., providing direct feedback during procedural training..
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: