Related Experiment Video
Updated: Dec 9, 2025

Measurement of Aerosols Optical Thickness of the Atmosphere using the GLOBE Handheld Sun Photometer
Published on: May 29, 2019
GOES-16/ABI Thermal Emissive Bands Assessments using GEO-LEO-GEO Double Difference
Tiejun Chang1, Xiaoxiong Xiong2
1Science Systems and Applications, Inc, Lanham, MD 20706.
Abstract:
Geostationary satellite (GOES)-16/ABI and Himawari-8/AHI represent a significant improvement over the imagers on board previous GOES. Their bands 7-16 are infrared channels covering the 3.9 to 13.3 μm spectral range and with a sub-point spatial resolution of 2 km. Their spectral coverage of the thermal emissive bands (TEB) are almost identical and both instruments employ similar calibration strategies using an on-board blackbody (BB) and a space look. The inter-comparison between the two instruments will be very helpful for their calibration assessments and their product quality enhancements. GOES-16 was launched on November 19, 2016, initially to a test position at 89.5° West and reached its operational position (longitude of 75.2° West) on December 11, 2017. The Himawari-8 spacecraft was launched on October 7, 2014 and the observation focuses on Asia-Pacific region. In this work, an inter-comparison of their TEB measurement is performed using double difference with Aqua MODIS. The same type of scenes are selected for the two instruments and their measurements with the closest observation times are compared with Aqua MODIS matching bands. The view angle effect is corrected and their spectral mismatching effect is estimated. The dependence on the scene uniformity is analyzed. The ABI-AHI differences are within 0.3K for bands 10 (7.35 μm), 11 (8.44 μm), 12 (9.64 μm), and 14 (11.24 μm), and up to 0.8K difference for bands 15 (12.38 μm) and 16 (13.28 μm). The ABI precision is better than AHI for all TEB and their image navigation and registration (INR) precisions are comparable. In general, the ABI performance before and after re-location is consistent.
More Related Videos
11:25Identification and Quantification of Decomposition Mechanisms in Lithium-Ion Batteries; Input to Heat Flow Simulation for Modeling Thermal Runaway
Published on: March 7, 2022
08:53Visualizing Cellular Gibberellin Levels Using the nlsGPS1 Förster Resonance Energy Transfer (FRET) Biosensor
Published on: January 12, 2019
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Flame Photometry: Lab
Atomic Emission Spectroscopy: Overview
Flame Photometry: Overview
Absorption of Radiation
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...