Related Experiment Video
Updated: Dec 9, 2025

Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
Published on: December 19, 2024
Rapid Assessment of Exercise State through Athlete's Urine Using Temperature-Dependent NIRS Technology
Lihe Ding1, Lei-Ming Yuan2, Yiye Sun2
1School of Physical Education & Sport Science, Wenzhou Medical University, Wenzhou 325035, China.
Abstract:
Athletes usually take nutritional supplements and perform the specialized training to improve the performance of sport. A quick assessment of their athletic status will help to understand the current physical function of athletes' status and the effect of nutritional supplementation. Human urine, as one of the most important body indicators, is composed of many metabolites, which can provide effective monitoring information for physical conditions. In this study, temperature-dependent near-infrared spectroscopy (NIRS) technology was used to collect the spectra of athlete's urine for evaluating the feasibility of rapidly detecting the exercise state of the basketball player. To obtain the detection results accurately, several chemometrics methods including principal component analysis (PCA), variables selection method of variable importance in projection (VIP), continuous 1D wavelet transform (CWT), and partial least square-discriminant analysis (PLS-DA) were employed to develop a classifier to distinguish the physical status of athletes. The optimal classifying results were obtained by wavelet-PLS-DA classifier, whose average precision, sensitivity, and specificity are all above 0.95, and the overall accuracy of all samples is 0.97. These results demonstrate that temperature-dependent NIRS can be used to rapidly assess the physical function of athlete's status and the effect of nutritional supplementation is feasible. It can be believed that temperature-dependent NIR spectroscopy will obtain applications more widely in the future.
More Related Videos
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...