Tertiary phosphorus removal to extremely low levels by coagulation-flocculation and cloth-filtration
T Fundneider1, L Alejo1, S Lackner1
1Chair of Wastewater Engineering, Technical University of Darmstadt, Institute IWAR, Franziska-Braun-Straße 7, D-64287 Darmstadt, Germany
Abstract:
Higher standards in the European Water Framework Directive and national directive demand advanced wastewater treatment for removal of nutrients and organic micropollutants before the discharge into water bodies. Systematic investigations regarding relative dosage and filtration processes for removal of flocculated solids are currently lacking. In this study, the performance of technologies for advanced removal of total phosphorus down to <100 μg/L with pile cloth-filtration (CF) and membrane filtration was verified and synergy effects for the removal of other contaminants were identified. The results show that an over-stoichiometric addition of coagulants of >5 mol Me3+/mol sRP was necessary to achieve soluble reactive phosphorus (sRP) concentrations of <50 μg/L in the effluent. After the coupled process of tertiary phosphorus removal and solids removal, the soluble non-reactive phosphorus (sNRP) concentration regulates the lowest total phosphorus effluent concentration. sNRP is also partially, but not completely, removed by the use of coagulants. CF has proven to be an alternative technology for the removal of phosphorus and total suspended solids below the detection limit.
Related Concept Videos
Coagulation
Factors Affecting Solubility
The Phosphorus Cycle
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Colloidal precipitates
Precipitation and Co-precipitation