Related Experiment Video
Updated: Dec 9, 2025

Measuring the Complete-arch Distortion of an Optical Dental Impression
Published on: May 30, 2019
Marginal discrepancy of 3-unit Co-Cr metal copings fabricated with additive and subtractive manners: A comparative
1Department of Prosthetic Dentistry, Faculty of Dentistry, Near East University, Nicosia, Mersin-10, Turkey.
Background:
Poor marginal adaptation may give rise to a series of biological complications. Despite its importance, comparative studies on marginal adaptation of metal-ceramic fixed restorations fabricated with newer methods are limited.
Aim:
Therefore, it was aimed to assess the marginal accuracy of copings fabricated with subtractive and additive manners used in contemporary dentistry.
Materials And Methods:
For a typodont model, 60 three-unit cobalt-chrome metal copings were fabricated by selective laser sintering (SLS), hard alloy milling (HAM), and soft alloy milling (SAM) in comparison to casting (C). Marginal discrepancy assessment was performed by using replication technique. Mesiodistal and buccopalatal cross-sections of silicone replicas were investigated under a stereomicroscope at × 80 magnification. A total of 960 measurements were subsequently made by means of corresponding image-review software on captured images after calibration of the software to μm scale. Obtained data were subjected to nonparametric Kruskal Wallis and Tamhane post-hoc tests (α =0.05).
Results:
Marginal adaptation of C group was significantly inferior to test groups in both canine- and premolar-teeth measurements (P < 0.05). Marginal fit was found to be tooth dependent (P < 0.001). HAM, SAM, and SLS groups exhibited analogous marginal discrepancy values on canine-tooth measurements. Differences among these groups were not statistically significant (P > 0.05). SAM and SLS groups demonstrated better marginal adaptation than others on premolar-tooth measurements. Also, no statistically significant difference was detected between SAM and SLS groups (P > 0.05).
Conclusions:
SAM group demonstrated superior marginal accuracy. All groups had clinically acceptable marginal discrepancy values (<120 μm), except cast group.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:02Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025