Related Experiment Video
Updated: Dec 9, 2025

Purification and Analytics of a Monoclonal Antibody from Chinese Hamster Ovary Cells Using an Automated Microbioreactor System
Published on: May 1, 2019
Determination of purity values of amino acid reference materials by mass balance method: an approach to the
Hong Liu1, Pui Sze Cheow1, Sharon Yong1
1Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore, 117528, Singapore.
Abstract:
A systematic procedure for the determination of purity values of amino acid reference materials was developed by use of mass balance method where four categories of impurities (related structure impurities (RSIs), water, organic solvent residue (OSR), and non-volatile residue (NVR)) were quantified separately. The amount of RSIs was determined using a combination of three quantification methods. To ensure metrological traceability in the determination of RSIs, at least one such impurity in each candidate amino acid reference material was quantified using liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS). Other RSIs were determined using external calibration liquid chromatography-tandem mass spectrometry (LC-MS/MS) or o-phthaldialdehyde (OPA) derivatization, followed by liquid chromatography-ultraviolet (LC-UV) measurement. As the UV absorption of most RSIs came basically from the same chromophore after OPA derivatization, a relative peak area approach was used in the LC-UV method to quantify the amount of RSIs by comparing their peak areas with that of a reference RSI. The reference RSI was pre-selected and the amount determined by LC-IDMS/MS separately. The absence of D-amino acids was confirmed using Marfey's reagent derivatization, followed by LC-UV analysis. The amounts of water, OSR, and NVR were measured using Karl Fischer coulometry, gas chromatography-mass spectrometry (GC-MS) and thermogravimetry, respectively. By using this procedure, four amino acid (L-valine, L-leucine, L-isoleucine, and L-phenylalanine) certified reference materials (CRMs) were developed from the candidate materials. The homogeneity and stability of the CRMs were demonstrated by use of LC-IDMS/MS or OPA-LC-UV method, following the principles in ISO 17034 and ISO Guide 35.Graphical abstract.
More Related Videos
12:47Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
11:14Mass Spectrometric Approaches to Study Protein Structure and Interactions in Lyophilized Powders
Published on: April 14, 2015
Related Concept Videos
Mass Spectrometry of Amines
Amines undergo fragmentation through α cleavage, producing nitrogen-containing cations—iminium ions—and alkyl radicals. Mass spectra of aromatic and cyclic aliphatic amines exhibit...
Mass Spectrometry: Amine Fragmentation
In amines, the number of nitrogen atoms affects the mass of the molecular ion, which is described by the nitrogen rule of mass spectrometry. This rule states that a compound containing a single...
Mass Spectrum: Interpretation
To...
Mass Spectrometry: Isotope Effect
High-Resolution Mass Spectrometry (HRMS)