Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Open and closed-loop control systems01:17

Open and closed-loop control systems

1.4K
Control systems are foundational elements in automation and engineering. They are broadly categorized into open-loop and closed-loop systems. These classifications hinge on the presence or absence of feedback mechanisms, significantly influencing the system's performance, complexity, and application.
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
1.4K
Heart Failure VI: Adjunct Therapies01:22

Heart Failure VI: Adjunct Therapies

149
Additional therapies for treating patients with heart failure (HF) may include procedural interventions, supplemental oxygen, the management of sleep disorders, and nutritional therapy.Procedural InterventionsImplantable Cardioverter-Defibrillator: For patients at risk of life-threatening arrhythmias due to severe left ventricular dysfunction, an Implantable Cardioverter-Defibrillator (ICD) can detect and terminate these arrhythmias, preventing sudden cardiac death and improving survival rates.
149
Hybridoma Technology01:31

Hybridoma Technology

16.7K
Hybridoma technology is used for the large-scale production of monoclonal antibodies. Monoclonal antibodies bind to only a single antigenic determinant or epitope. Such antibodies are used in research, diagnostics, and disease therapy. The hybridoma technology established in 1975 by Georges Köhler and Cesar Milstein was awarded the Nobel Prize in Medicine in 1984 for revolutionizing research and therapy.
Hybridoma Selection
Commonly used fusion techniques — electroporation,...
16.7K
Continuous Renal Replacement Therapy01:30

Continuous Renal Replacement Therapy

474
Continuous Renal Replacement Therapy, also known as CRRT, is a procedural treatment for acute kidney injury (AKI) that gradually removes uremic toxins and fluids while maintaining acid-base balance and stabilizing electrolytes. It is particularly useful for hemodynamically unstable patients. Unlike intermittent hemodialysis, which is faster, CRRT provides a gentler approach over 24 hours, closely mimicking the function of natural kidneys. However, CRRT is not ideal for patients with...
474
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen01:16

Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen

1.4K
Oxygen therapy is a pivotal aspect of medical care, particularly for patients with respiratory ailments. Two prominent oxygen-delivering systems include the Venturi mask and the transtracheal oxygen catheter.
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
1.4K
Two-Compartment Open Model: IV Infusion01:15

Two-Compartment Open Model: IV Infusion

449
A two-compartment model is a vital tool in pharmacokinetics, providing an essential understanding of drug behavior, especially for those administered via zero-order intravenous infusion. This model outlines two compartments: the central compartment, where elimination occurs, and the peripheral compartment.
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
449

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Participants' experiences of living with cystic fibrosis related diabetes and using a hybrid closed-loop system to support self-management: qualitative study.

BMC endocrine disorders·2026
Same author

Cambridge hybrid closed-loop use in very young children with type 1 diabetes: Parental expectancies during long-term home use.

Diabetic medicine : a journal of the British Diabetic Association·2026
Same author

Automated Insulin Delivery: Great Strides in the Past, Great Needs for the Future.

Diabetes care·2026
Same author

Insulin Bolus Patterns in Newly Diagnosed Youth With Type 1 Diabetes Using a Hybrid Closed-Loop Insulin Delivery System.

Journal of diabetes science and technology·2026
Same author

Relationship Between Laboratory-Measured HbA1c and Continuous Glucose Monitoring-Derived Glucose Management Indicator in Adults With Cystic Fibrosis-Related Diabetes.

Diabetes care·2026
Same author

Lived experience of fully closed-loop insulin delivery in adolescents with type 1 diabetes and HbA1c above target.

Diabetes research and clinical practice·2026
Same journal

Using a Fine-Tuned Commercial Artificial Intelligence Model to Assess Nutrients from Photographs of Japanese Meals.

Journal of diabetes science and technology·2026
Same journal

Diversity of Daily Glycemic Phenotypes Is Independently Associated With HbA1c: A Time-Resolved CGM Clustering Analysis.

Journal of diabetes science and technology·2026
Same journal

Continuous Glucose Monitoring and Early Dysglycemia: Toward an Emerging Stage Preceding Prediabetes.

Journal of diabetes science and technology·2026
Same journal

A Pilot Study on Disposal Practices and Environmental Awareness of Insulin-Related Devices Among People With Diabetes.

Journal of diabetes science and technology·2026
Same journal

Quality of In-Use Insulin Under Real-World Storage Conditions in Mwanza, Tanzania.

Journal of diabetes science and technology·2026
Same journal

Continuous Glucose Monitoring Metrics for Predicting Adverse Neonatal Outcomes in Individuals Undergoing Gestational Diabetes Screening.

Journal of diabetes science and technology·2026
See all related articles

Related Experiment Video

Updated: Dec 9, 2025

An Open-Source Normothermic Perfusion System Designed for Research Scientists
11:23

An Open-Source Normothermic Perfusion System Designed for Research Scientists

Published on: July 18, 2025

841

Training and Support for Hybrid Closed-Loop Therapy.

Charlotte K Boughton1,2, Sara Hartnell2, Janet M Allen1

  • 1Wellcome Trust-Medical Research Council Institute of Metabolic Science, University of Cambridge, Cambridge, UK.

Journal of Diabetes Science and Technology
|September 11, 2020
PubMed
Summary
This summary is machine-generated.

Hybrid closed-loop therapy offers significant benefits for type 1 diabetes (T1D) management. Effective training and clear expectations are crucial for users to achieve optimal glycemic control and quality of life with this technology.

Keywords:
artificial pancreashybrid closed-looptrainingtype 1 diabetes

More Related Videos

Author Spotlight: Therapeutic Benefit of Closed-Loop Deep Brain Stimulation in Depression Treatment
05:19

Author Spotlight: Therapeutic Benefit of Closed-Loop Deep Brain Stimulation in Depression Treatment

Published on: July 7, 2023

3.0K
Closed System Cell Culture Protocol Using HYPERStack Vessels with Gas Permeable Material Technology
11:48

Closed System Cell Culture Protocol Using HYPERStack Vessels with Gas Permeable Material Technology

Published on: November 29, 2010

19.1K

Related Experiment Videos

Last Updated: Dec 9, 2025

An Open-Source Normothermic Perfusion System Designed for Research Scientists
11:23

An Open-Source Normothermic Perfusion System Designed for Research Scientists

Published on: July 18, 2025

841
Author Spotlight: Therapeutic Benefit of Closed-Loop Deep Brain Stimulation in Depression Treatment
05:19

Author Spotlight: Therapeutic Benefit of Closed-Loop Deep Brain Stimulation in Depression Treatment

Published on: July 7, 2023

3.0K
Closed System Cell Culture Protocol Using HYPERStack Vessels with Gas Permeable Material Technology
11:48

Closed System Cell Culture Protocol Using HYPERStack Vessels with Gas Permeable Material Technology

Published on: November 29, 2010

19.1K

Area of Science:

  • Endocrinology
  • Biomedical Engineering
  • Diabetes Technology

Background:

  • Hybrid closed-loop (HCL) systems represent an advancement in type 1 diabetes (T1D) management.
  • Existing research indicates HCL therapy improves glycemic control and quality of life for individuals with T1D.
  • Clinical adoption and reimbursement depend on demonstrating and translating these benefits into practice.

Purpose of the Study:

  • To outline essential training and support strategies for users of commercial HCL systems.
  • To identify key considerations for successful implementation of HCL therapy in clinical practice.
  • To discuss the potential beneficiaries of HCL technology.

Main Methods:

  • Review of key training and support aspects for commercially available HCL systems.
  • Discussion of foundational diabetes management skills in the context of HCL therapy.
  • Analysis of factors influencing long-term HCL system usage and outcomes.

Main Results:

  • High-quality training is paramount for maximizing HCL therapy benefits.
  • Reinforcement of basic diabetes management skills is critical for HCL users.
  • Setting clear expectations regarding HCL system capabilities and limitations is vital for user success.

Conclusions:

  • Effective training and user support are essential for optimal outcomes with HCL therapy.
  • HCL technology has the potential to significantly improve T1D management.
  • Further efforts are needed to facilitate access and integration of HCL systems into routine care.