Related Experiment Video
Updated: Dec 9, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Enhanced Masses on Contrast-Enhanced Breast: Differentiation Using a Combination of Dynamic Contrast-Enhanced MRI and
Megumi Matsuda1, Takaharu Tsuda1, Rui Ebihara1
1Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan.
Background:
The addition of synthetic MRI might improve the diagnostic performance of dynamic contrast-enhanced MRI (DCE-MRI) in patients with breast cancer.
Purpose:
To evaluate the diagnostic value of a combination of DCE-MRI and quantitative evaluation using synthetic MRI for differentiation between benign and malignant breast masses.
Study Type:
Retrospective, observational.
Population:
In all, 121 patients with 131 breast masses who underwent DCE-MRI with additional synthetic MRI were enrolled.
Field Strength/Sequence:
3.0 Tesla, T1 -weighted DCE-MRI and synthetic MRI acquired by a multiple-dynamic, multiple-echo sequence.
Assessment:
All lesions were differentiated as benign or malignant using the following three diagnostic methods: DCE-MRI type based on the Breast Imaging-Reporting and Data System; synthetic MRI type using quantitative evaluation values calculated by synthetic MRI; and a combination of the DCE-MRI + Synthetic MRI types. The diagnostic performance of the three methods were compared.
Statistical Tests:
Univariate (Mann-Whitney U-test) and multivariate (binomial logistic regression) analyses were performed, followed by receiver-operating characteristic curve (AUC) analysis.
Results:
Univariate and multivariate analyses showed that the mean T1 relaxation time in a breast mass obtained by synthetic MRI prior to injection of contrast agent (pre-T1 ) was the only significant quantitative value acquired by synthetic MRI that could independently differentiate between malignant and benign breast masses. The AUC for all enrolled breast masses assessed by DCE-MRI + Synthetic MRI type (0.83) was significantly greater than that for the DCE-MRI type (0.70, P < 0.05) or synthetic MRI type (0.73, P < 0.05). The AUC for category 4 masses assessed by the DCE-MRI + Synthetic MRI type was significantly greater than that for those assessed by the DCE-MRI type (0.74 vs. 0.50, P < 0.05).
Data Conclusion:
A combination of synthetic MRI and DCE-MRI improves the accuracy of diagnosis of benign and malignant breast masses, especially category 4 masses. Level of Evidence 4 Technical Efficacy Stage 2 J. MAGN. RESON. IMAGING 2021;53:381-391.

