Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Cascaded Op Amps01:16

Cascaded Op Amps

953
Operational amplifiers (op-amps) are versatile electronic components that can be interconnected in a cascade - one after another in a linear sequence. This cascading is possible due to their infinite input resistance and zero output resistance, allowing them to maintain their input-output relationships even when connected in series.
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
953

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Zcf24, a zinc-finger transcription factor, is required for lactate catabolism and inhibits commensalism in Candida albicans.

Molecular microbiology·2022
Same author

Human reliability assessment of intelligent coal mine hoist system based on Bayesian network.

Scientific reports·2022
Same author

Application of Deep Learning on Single-cell RNA Sequencing Data Analysis: A Review.

Genomics, proteomics & bioinformatics·2022
Same author

Distinct clinical pattern of colorectal cancer patients with POLE mutations: A retrospective study on real-world data.

Frontiers in genetics·2022
Same author

Natural oscillation frequencies of a Rayleigh sphere levitated in standing acoustic waves.

The Journal of the Acoustical Society of America·2022
Same author

Design and Synthesis of Fibroblast Growth Factor Receptor (FGFR) and Histone Deacetylase (HDAC) Dual Inhibitors for the Treatment of Cancer.

Journal of medicinal chemistry·2022

Related Experiment Video

Updated: Dec 9, 2025

A Silicon-tipped Fiber-optic Sensing Platform with High Resolution and Fast Response
09:03

A Silicon-tipped Fiber-optic Sensing Platform with High Resolution and Fast Response

Published on: January 7, 2019

7.5K

Thermo-Optical Tuning Cascaded Double Ring Sensor with Large Measurement Range.

Zhiping Yang1, Yanlu Wang1, Chang Su2

  • 1Department of Optical Engineering, School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130022, China.

Sensors (Basel, Switzerland)
|September 12, 2020
PubMed
Summary

This study introduces a thermo-optic tuning optical waveguide sensor using cascaded micro-ring resonators. The enhanced system achieves significantly higher sensitivity and measurement range for refractive index detection.

Keywords:
cascaded double micro-ring resonatorintensity interrogationoptical waveguidethermo-optical tuning

More Related Videos

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
09:48

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping

Published on: November 7, 2016

12.3K
Fabrication and Testing of Photonic Thermometers
08:44

Fabrication and Testing of Photonic Thermometers

Published on: October 24, 2018

6.1K

Related Experiment Videos

Last Updated: Dec 9, 2025

A Silicon-tipped Fiber-optic Sensing Platform with High Resolution and Fast Response
09:03

A Silicon-tipped Fiber-optic Sensing Platform with High Resolution and Fast Response

Published on: January 7, 2019

7.5K
Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
09:48

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping

Published on: November 7, 2016

12.3K
Fabrication and Testing of Photonic Thermometers
08:44

Fabrication and Testing of Photonic Thermometers

Published on: October 24, 2018

6.1K

Area of Science:

  • Photonics and optical sensing technologies.
  • Integrated optics and waveguide devices.
  • Microfluidics for lab-on-a-chip applications.

Background:

  • Investigates a thermo-optic tuning optical waveguide sensor system.
  • Features a cascaded double micro-ring resonator design.
  • Incorporates a microheater as a reference ring and a sensing ring with modified cladding, coupled with microfluidic control.

Discussion:

  • The sensor system leverages thermo-optic effects for refractive index (RI) sensing.
  • Refractive index changes are detected via alterations in microheater electric power.
  • The cascaded design enhances sensitivity and measurement range compared to non-tuned systems.

Key Insights:

  • Achieved a sensitivity of 34.231 W/RIU.
  • Demonstrated a measurement range of 4.325 × 10-3 RIU.
  • The thermo-optic tuning significantly expands the measurement range by approximately eight times.

Outlook:

  • Potential for advanced chemical and biological sensing applications.
  • Further optimization of microheater integration and microfluidic control.
  • Exploration of alternative interrogation methods for enhanced performance.