Highly improved aqueous lubrication of polymer surface by noncovalently bonding hyaluronic acid-based hydration layer
Yan-Pu Li1, Wei Liu1, Ya-Hui Liu1
1College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu, 610065, China.
Abstract:
Hydration lubrication is the key responsible for the exceptionally low boundary friction between biosurfaces. However, it is a challenge to settle a hydration layer on a polymer surface via a noncovalent manner. Herein, we develop a highly lubricated coating absorbed onto the polymer surface via intermolecular association of hyaluronic acid (HA)-based micelles. A poly(ethylene oxide)-b-poly(propylene oxide)-b-poly(ethylene oxide) triblock copolymer (Pluronic, F127) is recruited to complex with HA and further self-assembled to form a thick micelle layer. High water-retaining capacity of the HA/F127 coating enables the decorated surface with excellent hydrophilicity and boundary lubrication, where the coefficient of friction in aqueous media is reduced by 60% compared with the bare polymer surface. The HA/F127 coating suppresses nonspecific protein adsorption and exhibits good biocompatibility. More remarkably, an in vivo cynomolgus monkey model, demonstrates the utility of the HA/F127 coating in alleviating or preventing complications of endotracheal intubation, such as foreign irritation, airway mucosal damage, and inflammatory response. This cost-effective and scalable approach is suitable to manufacture interventional devices especially disposable medical devices with highly lubricated surface.
More Related Videos
05:43Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
12:19Multi-Scale Modification of Metallic Implants With Pore Gradients, Polyelectrolytes and Their Indirect Monitoring In vivo
Published on: July 1, 2013
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
