Related Experiment Video
Updated: Dec 9, 2025

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Investigating the Impact of Gadolinium-Based Contrast Agents on the Corrected QT Interval
Kyle L Gress1, Tyler Gallo2, Ivan Urits3
1Department of Pharmacology, Georgetown University School of Medicine, Washington, DC, USA.
Abstract:
Introduction The manufacturing labels for all currently marketed gadolinium-based MRI contrast agents describe adverse cardiac events reported during post-market use. The goal of this study was to determine prolongation of the rate-corrected QT interval occurs in the immediate setting after gadolinium-based MRI contrast agent injection. Methods This study enrolled adults scheduled to have a gadolinium-based MRI contrast agent injection as part of a diagnostic MRI. A single-lead electrocardiogram was recorded using the AliveCor Kardia® ECG (Mountain View, CA) device before and after injection. The rate-corrected QT interval was subsequently measured by two independent investigators. The QT interval was corrected for rate using the two most common formulas, originally cited by Bazett and Fridericia. These rate-corrected QT intervals from before and after gadolinium-based MRI contrast agent injection were compared using the Wilcoxon signed-rank test paired analysis. Results A total of 24 consenting adults had electrocardiogram that were free of motion artifact. The mean age of the final patient cohort was 59.4 years. There was an equal split of 12 men and 12 women. The mean pre-injection, rate-corrected QT interval, corrected using Bazett's formula, was 395 msec. The mean post-injection, rate-corrected QT interval, corrected using Bazett's formula, was 396 msec. The corrections using Fridericia's formula were 384 and 381 msec, respectively. There was no statistically significant change in Bazett-corrected QT interval (QTc-B) when pre-injection and post-injection values were directly compared. Discussion The results of the present investigation support the conclusion that gadolinium-based MRI contrast agents do not commonly affect rate-corrected QT interval in routine clinical use. While the frequency of rate-corrected QT interval prolongation might be overstated, the severity of adverse events is definitively not. A role for concomitant rate-corrected QT interval-prolonging drugs or unidentified rare factors such as genetic predisposition cannot be ruled out. The limitations of this study include its relatively small size and the implementation of a single-lead electrocardiogram to measure rate-corrected QT interval. Conclusion The present investigation revealed that significant rate-corrected QT interval prolongation, while previously reported in as many as 55% of patients after gadolinium-based MRI contrast agent injection, is not a common occurrence in the routine clinical setting.
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Antiarrhythmic Drugs: Class I Agents as Sodium Channel Blockers
Class 1A Antiarrhythmic Drugs: These drugs work by moderately blocking sodium channels,...
Antiarrhythmic Drugs: Class III Agents as Potassium Channel Blockers
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...

