Experimental data on the development of "Post-installed Screw Pullout test" for in-situ investigation of concrete
Shah Nur Alam Sourav1,2, Salam Al-Sabah1,2, Ciaran McNally1
1School of Civil Engineering, University College Dublin, Belfield, Dublin 4, Ireland.
Abstract:
This data article describes the datasets obtained during the development phase of "Post-installed Screw Pullout (PSP) test", a new in-situ test for concrete strength assessment. The datasets presented focus on the results obtained in mortar samples. The presented PSP test method is based on a post-installed screw being pulled from the parent material. To implement this, the screws installed in mortar sample were loaded to failure and the responses were recorded in the form of load-displacement curves. The samples were tested for two types of screw under different test conditions, with variables that included hole depth, hole diameter and mortar strength. These datasets are associated with the article "The Post-installed Screw Pullout Test: Development of a Method for Assessing In-situ Concrete Compressive Strength" (Al-Sabah et al., 2020).
Related Concept Videos
Non-destructive Tests for Concrete Strength
Impact Strength of Concrete
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...