Measurement of cartilage sub-component distributions through the surface by Raman spectroscopy-based multivariate
Daniel Mason1, Sangeeta Murugkar2, Andrew D Speirs1
1Department of Mechanical and Aerospace Engineering, Carleton University, Ottawa, Canada.
Abstract:
Articular cartilage posesses unique material properties due to a complex depth-dependent composition of sub-components. Raman spectroscopy has proven valuable in quantifying this composition through cartilage cross-sections. However, cross-sectioning requires tissue destruction and is not practical in situ. In this work, Raman spectroscopy-based multivariate curve resolution (MCR) was employed in porcine cartilage samples (n = 12) to measure collagen, glycosaminoglycan, and water distributions through the surface for the first time; these were compared against cross-section standards. Through the surface Raman measurements proved reliable in predicting composition distribution up to a depth of approximately 0.5 mm. A fructose-based optical clearing agent (OCA) was also used in an attempt to further improve depth of resolution of this measurement method. However, it did not; mainly due to a high-spectral overlap with the Raman spectra of main cartilage sub-components. This measurement technique potentially could be used in situ, to better understand the etiology of joint diseases such as osteoarthritis (OA).
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Spectroscopy of Carboxylic Acid Derivatives
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Growth of Cartilage and Bone Tissue
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...