SiameseGAN: A Generative Model for Denoising of Spectral Domain Optical Coherence Tomography Images
Related Experiment Video
Updated: Dec 9, 2025

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
Published on: January 15, 2013
Abstract:
Optical coherence tomography (OCT) is a standard diagnostic imaging method for assessment of ophthalmic diseases. The speckle noise present in the high-speed OCT images hampers its clinical utility, especially in Spectral-Domain Optical Coherence Tomography (SDOCT). In this work, a new deep generative model, called as SiameseGAN, for denoising Low signal-to-noise ratio (LSNR) B-scans of SDOCT has been developed. SiameseGAN is a Generative Adversarial Network (GAN) equipped with a siamese twin network. The siamese network module of the proposed SiameseGAN model helps the generator to generate denoised images that are closer to groundtruth images in the feature space, while the discriminator helps in making sure they are realistic images. This approach, unlike baseline dictionary learning technique (MSBTD), does not require an apriori high-quality image from the target imaging subject for denoising and takes less time for denoising. Moreover, various deep learning models that have been shown to be effective in performing denoising task in the SDOCT imaging were also deployed in this work. A qualitative and quantitative comparison on the performance of proposed method with these state-of-the-art denoising algorithms has been performed. The experimental results show that the speckle noise can be effectively mitigated using the proposed SiameseGAN along with faster denoising unlike existing approaches.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...

