Abstract:
Sentinel lymph node (SLN) mapping by various means has become standard of care in certain types of human cancers and is receiving more attention in veterinary oncology. Current SLN mapping techniques can be costly and often require advanced imaging equipment. The objective of this prospective, method comparison study was to compare an SLN mapping protocol of lymphoscintigraphy to lymphography using water soluble iodinated contrast medium (WIC) and digital radiography for identification of an SLN. Lymphoscintigraphy and lymphography were performed on eight healthy purpose-bred dogs using technetium-99m sulfur colloid and WIC injected into the subcutaneous tissues in a four-quadrant technique around a predefined area of skin on the brachium. Images were obtained using a gamma camera and digital radiography at different time points post-injection. Image sequences were evaluated by one of two American College of Veterinary Radiology board-certified veterinary radiologists. Data obtained were compared between methods using descriptive statistics. An SLN was identified in all dogs with lymphoscintigraphy and seven of eight dogs with lymphography. Agreement between results of the lymphoscintigraphy and lymphography studies was a complete match in three dogs, a partial match in four dogs, and no match in one dog. The SLN detected differed based on the imaging modality used.
More Related Videos
06:37Multispectral Real-time Fluorescence Imaging for Intraoperative Detection of the Sentinel Lymph Node in Gynecologic Oncology
Published on: October 20, 2010
10:05Three-Dimensional Imaging of the Vertebral Lymphatic Vasculature and Drainage using iDISCO+ and Light Sheet Fluorescence Microscopy
Published on: May 22, 2020
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...