Related Experiment Video
Updated: Dec 9, 2025

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
Colorimetric speciation analysis of chromium using 2-thiobarbituric acid capped silver nanoparticles
Kamal Mousapour1, Salahaddin Hajizadeh2, Khalil Farhadi3
1Department of Chemistry, Payame Noor University, Sari, Iran.
This study introduces 2-thiobarbituric acid-capped silver nanoparticles (AgNPs) as a novel nanoprobe for detecting chromium ions. The developed colorimetric sensor offers a sensitive and selective method for quantifying chromium(iii) and chromium(vi) in wastewater.
Area of Science:
- Materials Science
- Analytical Chemistry
- Nanotechnology
Background:
- Chromium ions (Cr(iii) and Cr(vi)) are significant environmental pollutants.
- Developing sensitive and selective sensors for chromium detection is crucial for environmental monitoring.
- Silver nanoparticles (AgNPs) offer unique optical properties suitable for sensor applications.
Purpose of the Study:
- To develop a novel colorimetric sensor for the sensitive and selective detection of Cr(iii) and Cr(vi) ions.
- To utilize 2-thiobarbituric acid (TBA)-capped silver nanoparticles (AgNPs) as a nanoprobe.
- To investigate the interaction mechanism and optimize detection parameters.
Main Methods:
- Synthesis and characterization of 2-thiobarbituric acid (TBA)-capped silver nanoparticles (AgNPs).
- Colorimetric detection of Cr(iii) via AgNPs aggregation, monitored by UV-Vis spectrophotometry.
- Determination of Cr(vi) in the presence of ascorbic acid (AA) as a reducing agent.
- Utilizing FT-IR and transmission electron microscopy (TEM) for characterization and mechanism elucidation.
- Application of EDTA as a masking agent for Cr(iii) determination and optimization of detection ranges.
Main Results:
- A linear relationship was established for Cr(iii) detection (0.012–3.25 mg L⁻¹) with a limit of detection (LOD) of 8.4 µg L⁻¹.
- The sensor showed a distinct color change from yellow to pinkish red upon Cr(iii) interaction.
- Cr(vi) was detected in the concentration range of 0.20–1.40 mg L⁻¹.
- The developed sensor was successfully applied to analyze Cr(iii) and Cr(vi) in cement factory wastewater samples.
Conclusions:
- TBA-AgNPs serve as an effective nanoprobe for a sensitive and selective colorimetric sensor for Cr(iii) and Cr(vi).
- The method demonstrates good performance and applicability for real-world environmental samples.
- This approach offers a promising tool for the rapid and cost-effective monitoring of chromium contamination.
More Related Videos
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry CE-ICP-MS for Quantification of Iron Redox Species FeII, FeIII
Published on: May 4, 2020
05:08Measurement of Tissue Non-Heme Iron Content using a Bathophenanthroline-Based Colorimetric Assay
Published on: January 31, 2022
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Precipitation Titration Curve: Analysis
Qualitative Analysis
For instance, group IV...
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is: