Related Experiment Video
Updated: Dec 9, 2025

Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Derivatization and rapid GC-MS screening of chlorides relevant to the Chemical Weapons Convention in organic liquid
Marja-Leena Kuitunen1, Jorgelina Cecilia Altamirano2,3, Peter Siegenthaler4
1VERIFIN, Department of Chemistry, University of Helsinki, P.O. Box 55, FIN-00014 Helsinki, Finland. Marja-Leena.Kuitunen@alumni.helsinki.fi.
Abstract:
A simple derivatization technique was developed for the analysis of seven Schedule 3 chemicals and one Schedule 2 chemical listed in the Chemical Weapons Convention (CWC). Phosgene, phosphorus oxychloride, phosphorus trichloride, phosphorus pentachloride, thionyl chloride, sulfur monochloride and sulfur dichloride (Schedule 3) as well as arsenic trichloride (Schedule 2) were derivatized using 1-propanol in 40% pyridine solution for analysis with gas chromatography-mass spectrometry (GC-MS). Derivatization temperature and concentration of the derivatization solution were optimized for maximum derivatization recovery. The stabilities of the target analytes and their derivatives in different solvents were studied. The derivatization yield showed a linear response within the analyte concentration range of 0.1-2 mM (10-200 μg ml-1) with correlation coefficients >0.99 (r2), except for AsCl3 which did not show a linear response after derivatization. Good reproducibility with relative standard deviations (RSDs) from 3 to 13% was achieved. The derivatization recovery was 66% for phosgene and 67-80% for the P-containing chemicals phosphorus oxychloride, phosphorus trichloride and phosphorus pentachloride. Recommendations to use the method for screening the presence of these chemicals in organic liquid samples are given. The method is used when CWC-related samples are screened at VERIFIN.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:06GC-based Detection of Aldononitrile Acetate Derivatized Glucosamine and Muramic Acid for Microbial Residue Determination in Soil
Published on: May 19, 2012
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...