Related Experiment Video
Updated: Dec 9, 2025

Optimized Griess Reaction for UV-Vis and Naked-eye Determination of Anti-malarial Primaquine
Published on: October 11, 2019
Portable and benchtop Raman spectrometers coupled to cluster analysis to identify quinine sulfate polymorphs in solid
Sarmento J Mazivila1, Helena I S Nogueira2, Ricardo N M J Páscoa3
1Centro de Investigação em Química da Universidade do Porto (CIQ-UP), Research Centre in Chemistry (CIQ-UP), Faculty of Sciences, University of Porto, R. Campo Alegre 687, 4169-007 Porto, Portugal. mazivilasarmentojunior@yahoo.com.br sarmento.mazivila@fc.up.pt jcsilva@fc.up.pt.
Abstract:
This paper proposes for the first time: (a) a qualitative analytical method based on portable and benchtop backscattering Raman spectrometers coupled to hierarchical cluster analysis (HCA) and multivariate curve resolution - alternating least-squares (MCR-ALS) to identify two polymorphs of antimalarial quinine sulfate in commercial pharmaceutical tablets in their intact forms and (b) a quantitative analytical method based on gold nanoparticles (AuNPs) as active substrates for surface-enhanced Raman scattering (SERS) in combination with MCR-ALS to quantify quinine sulfate in commercial pharmaceutical tablets in solution. The pure concentration and spectral profiles recovered by MCR-ALS proved that both formulations present different polymorphs. These results were also confirmed by two clusters observed in the HCA model, according to their similarities within and among the samples that provided useful information about the homogeneity of different pharmaceutical manufacturing processes. AuNPs-SERS coupled to MCR-ALS was able to quantify quinine sulfate in the calibration range from 150.00 to 200.00 ng mL-1 even with the strong overlapping spectral profile of the background SERS signal, proving that it is a powerful ultrahigh sensitivity analytical method. This reduced linearity was validated throughout a large calibration range from 25.00 to 175.00 μg mL-1 used in a reference analytical method based on high performance liquid chromatography with a diode array detector (HPLC-DAD) coupled to MCR-ALS for analytical validation purposes, even in the presence of a coeluted compound. The analytical methods developed herein are fast, because second-order chromatographic data and first-order SERS spectroscopic data were obtained in less than 6 and 2 min, respectively. Concentrations of quinine sulfate were estimated with low root mean square error of prediction (RMSEP) values and a low relative error of prediction (REP%) in the range 1.8-4.5%.
More Related Videos
06:15Author Spotlight: Advancements and Applications in Nanoparticle Synthesis Through Laser Ablation in Liquids
Published on: June 16, 2023
07:37An Integrated Raman Spectroscopy and Mass Spectrometry Platform to Study Single-Cell Drug Uptake, Metabolism, and Effects
Published on: January 9, 2020