Related Experiment Video
Updated: Dec 9, 2025

Author Spotlight: Technologies and Challenges in Elemental Analysis of Food Samples
Published on: December 22, 2023
Multivariate optimization of an analytical method for the analysis of Abruzzo white wines by ICP OES
Fabrizio Ruggieri1, Angelo Antonio D'Archivio1, Martina Foschi1
1Dipartimento di Scienze Fisiche e Chimiche, Università degli Studi dell'Aquila, Via Vetoio, 67010 Coppito, L'Aquila, Italy. fabrizio.ruggieri@univaq.it.
Abstract:
An inductively coupled plasma-optical emission spectrometry (ICP OES) method was optimized and applied for determining the concentration of 14 elements (Ba, Ca, Co, Cu, Fe, K, Li, Mg, Mn, Na, Ni, Sr, V, and Zn) in three representative white wines of the Abruzzo region (Italy). In order to optimise an ICP OES method a three level factorial design for three variables was used. The intensity of the emission lines for analytes was simultaneously maximised by using Derringer's desirability function. Using this approach, the optimal experimental conditions for wine analysis of 0.48 L min-1, 1.8 mL min-1 and 0.5 L min-1 for the nebulizer gas flow rate, sample uptake rate and auxiliary gas flow rate respectively were achieved. A total of 46 white wine samples of the three varieties were analysed by using the optimised experimental conditions. Linear Discriminant Analysis (LDA) and Partial Least Squares Linear Discriminant Analysis (PLS LDA) allowed an acceptable classification of the three varietal samples.
More Related Videos
13:02The Terroir Concept Interpreted through Grape Berry Metabolomics and Transcriptomics
Published on: October 5, 2016
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Development of Analytical Methods
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview