Face Mask Leak Determines Aerosol Delivery in Noninvasive Ventilation
Alexandra Haw1, Michael McPeck2, Ann D Cuccia3
1Division of Pulmonary, Critical Care, and Sleep Medicine, Department of Medicine, Stony Brook University Medical Center, Stony Brook, New York. alexandra.haw@stonybrookmedicine.edu.
Background:
Aerosol transport during noninvasive ventilation follows the flow of pressurized gas through the noninvasive ventilation circuit, vented via leak port and face mask, and inhaled by the patient. Recommendations for nebulizer placement are based on in vitro models that have focused primarily on aerosol losses via the leak port; face mask leaks have been avoided. This study tested aerosol delivery in the setting of controlled face mask leak.
Methods:
Three nebulizer technologies were studied on a bench model using a lung simulator with a face mask placed onto a manikin head. Radiolabeled aerosol delivery (ie, inhaled mass) was determined by mass balance using filters and a gamma camera that tested the effects of nebulizer location and face mask leak. Low (15-20 L/min) and high (55-60 L/min) mask leaks were used to mimic realistic clinical conditions.
Results:
Inhaled mass (% nebulizer charge) was a function of nebulizer technology (with the nebulizer at ventilator outlet position: Aerogen 22.8%, InspiRx 11.1%, and Hudson 8.1%; P = .001). The location of the nebulizer before or after the leak port was not important (P = 0.13 at low leak and P = 0.38 at high leak). Aerosol delivery was minimal with high mask leak (inhaled mass 1.5-7.0%). Aerosol losses at the leak port at low mask leak were 28-36% versus 9-24% at high mask leak. Aerosol losses via the mask leak were 16-20% at low mask leak versus 46-72% at high mask leak. Furthermore, high face mask leak led to significant deposition on the mask and face (eg, up to 50% of the nebulizer charge with the Aerogen mask).
Conclusions:
During noninvasive ventilation, nebulizer placement at the ventilator outlet, which is a more practical position, is effective and minimizes deposition on face and mask. Aerosol therapy should be avoided when there is high face mask leak.
More Related Videos
15:04Modeling and Simulations of Olfactory Drug Delivery with Passive and Active Controls of Nasally Inhaled Pharmaceutical Aerosols
Published on: May 20, 2016
04:56Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Mechanical Ventilation I: Indication and Settings