Related Experiment Video
Updated: Dec 8, 2025

Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
Effectiveness of a radiation protective device for anesthesiologists and transesophageal echocardiography operators
Hitoshi Miyazaki1, Yoshiyuki Umezu2, Emi Kinoshita3
1Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. mhitoshi@med.kyushu-u.ac.jp.
Abstract:
In structural heart disease (SHD) interventions, the exposure of staff other than the first operator such as anesthesiologists and transesophageal echocardiography (TEE) operators to the radiation can also pose the risks of cancer and cataracts in the long term. This study was conducted to test our new radiation protective device (RPD) for anesthesiologists and TEE operators in SHD interventions. The RPD, which consists of a head side shield and a cradle shield, was mounted on a 0.25 mm Pb-equivalent unleaded radiation protection sheet on a self-made J-shaped acrylic table, and it was placed on the head side and cradle on the operating table. A CT human body phantom was placed on the operating table, and the C-arm was set in five directions: posteroanterior, right anterior oblique 30°, left anterior oblique 30°, caudal 30°, and cranial 30°. The ambient dose equivalent rate at the usual positions of the anesthesiologist and TEE operator were measured under a fluoroscopic sequence with and without the RPD, and the dose reduction rate was obtained. The height of each measurement point was set to 100, 130 or 160 cm. The reduction rates at the positions of the anesthesiologist and the TEE operator were 82.6-86.4% and 77.9-89.5% at the height of 100 cm, 48.5-68.4% and 83.3-91.0% at 130 cm, and 23.6-62.9% and 72.9-86.1% at 160 cm, respectively. The newly developed RPD can thus effectively reduce the radiation exposure of anesthesiologists and TEE operators during SHD interventions.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System V: CT
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

