Comparison of the Visual Performance after Implantation of Three Aberration-correcting Aspherical Intraocular Lens
Yuqi Liu1, Jiangyue Zhao1, Yiping Hu1
1Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University and the Key Lenticular Laboratory of Liaoning Province , Shenyang, China.
Purpose:
To compare the visual performance after implantation of three aberration-correcting aspherical intraocular lens (IOL).
Materials And Methods:
Seventy-seven eyes of 77 cataract patients were divided into three groups: 26 eyes implanted with a non-constant aberration IOL (LUCIA 601P IOL, Zeiss Company, Germany); 26 eyes implanted with a spherical aberration -0.18μm IOL (CT ASPHINA 509M, Zeiss Company, Germany) and 27 eyes implanted with a spherical aberration -0.27μm IOL (AMO Tecnis ZCB00, Johnson & Johnson Surgical Vision, USA). Three months after operation, the distance visual acuity, wavefront aberrometry, contrast sensitivity, intraocular stray light, IOL decentration, and tilt were evaluated.
Results:
Three months postoperatively, no statistically significant differences were found in uncorrected distance visual acuity and corrected distance visual acuity (p≥.83). The RMS for total ocular coma was statistically significantly lower in the Lucia group (p=.03) and spherical aberration was statistically significantly lower in the Tecnis group (p<.01). No statistically significant differences were observed among the three lenses in higher order aberration (p=.85) and in contrast sensitivity under both photopic and mesopic lighting conditions (p≥.05). The intraocular stray light was statistically significantly better in the Lucia group (p=.04). No statistically significant differences were observed with respect to IOL decentration (p=.75) and tilt (p=.89).
Conclusions:
Cataract surgery with non-constant aberration IOL resulted in lower coma and better intraocular stray light than with the spherical aberration -0.18μm and -0.27μm IOLs despite equivalent postoperative levels of visual acuity and contrast sensitivity.
More Related Videos
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
06:19Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Focusing of Light in the Eye