Related Experiment Video
Updated: Dec 8, 2025

Evaluation of Colorectal Cancer Risk and Prevalence by Stool DNA Integrity Detection
Published on: June 8, 2020
DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA
Rejane Mattar1, Sergio Barbosa Marques2, Maurício Kazuyoshi Minata2
1Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP), Divisão de Gastroenterologia e Hepatologia Clínica, São Paulo, SP, Brasil.
Background:
Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening.
Objective:
Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test.
Methods:
Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings.
Results:
Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant.
Conclusion:
The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence.
More Related Videos
04:57Comparative Analysis of Automatic Fecal Analyzer versus Direct Wet Smear Microscopy for Detecting Parasitic Infections in Stool Samples
Published on: April 25, 2025
08:08qPCR Is a Sensitive and Rapid Method for Detection of Cytomegaloviral DNA in Formalin-fixed, Paraffin-embedded Biopsy Tissue
Published on: July 9, 2014