Related Experiment Video
Updated: Dec 8, 2025

Determining the Likelihood of Variant Pathogenicity Using Amino Acid-level Signal-to-Noise Analysis of Genetic Variation
Published on: January 16, 2019
Systematic Evaluation of KCNQ1 Variant Using ACMG/AMP Guidelines and Risk Stratification in Long QT Syndrome Type 1
Asami Kashiwa1, Takeshi Aiba2, Hisaki Makimoto2
1Department of Cardiovascular Medicine, National Cerebral & Cardiovascular Center, Suita & Department of Cardiovascular & Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan.
Abstract:
Background - Mutation/variant-site specific risk stratification in long-QT syndrome type 1 (LQT1) has been well investigated, but it is still challenging to adapt current enormous genomic information to clinical aspects caused by each mutation/variant. We assessed a novel variant-specific risk stratification in LQT1 patients. Methods - We classified a pathogenicity of 141 KCNQ1 variants among 927 LQT1 patients (536 probands) based on the American College of Medical Genetics and Genomics (ACMG) and Association for Molecular Pathology (AMP) guidelines and evaluated whether the ACMG/AMP-based classification was associated with arrhythmic risk in LQT1 patients. Results - Among 141 KCNQ1 variants, 61 (43.3%), 55 (39.0%), and 25 (17.7%) variants were classified into pathogenic (P), likely pathogenic (LP), and variant of unknown significance (VUS), respectively. Multivariable analysis showed that proband (HR = 2.53; 95%CI = 1.94-3.32; p <0.0001), longer QTc (≥500ms) (HR = 1.44; 95%CI = 1.13-1.83; p = 0.004), variants at membrane spanning (MS) (vs. those at N/C terminus) (HR = 1.42; 95%CI = 1.08-1.88; p = 0.01), C-loop (vs. N/C terminus) (HR = 1.52; 95%CI = 1.06-2.16; p = 0.02), and P variants [(vs. LP) (HR = 1.72; 95%CI = 1.32-2.26; p <0.0001), (vs. VUS) (HR = 1.81; 95%CI = 1.15-2.99; p = 0.009)] were significantly associated with syncopal events. The ACMG/AMP-based KCNQ1 evaluation was useful for risk stratification not only in family members but also in probands. A clinical score (0~4) based on proband, QTc (≥500ms), variant location (MS or C-loop) and P variant by ACMG/AMP guidelines allowed identification of patients more likely to have arrhythmic events. Conclusions - Comprehensive evaluation of clinical findings and pathogenicity of KCNQ1 variants based on the ACMG/AMP-based evaluation may stratify arrhythmic risk of congenital long-QT syndrome type 1.
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Antiarrhythmic Drugs: Class III Agents as Potassium Channel Blockers
Cardiomyopathy III: Hypertrophic Cardiomyopathy

