Related Experiment Video
Updated: Dec 8, 2025

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Preconcentration and determination of pyrethroid insecticides in with ionic liquid dispersive liquid-phase
Qingxiang Zhou1,2, Xiaoguo Zhang3, Guohong Xie4
1State Laboratory of Petroleum Resource and Prospecting, College of Geosciences, China University of Petroleum Beijing, Beijing, 102249, China. zhouqx@cup.edu.cn.
Abstract:
This paper developed a new method with temperature controlled ionic liquid dispersive liquid-phase microextraction for the determination of pyrethroid insecticides such as fenpropathrin, fenvalerate and bifenthrin in water samples. The effect of alkyl chain length of ionic liquid 1-alkyl-3-methylimidazolium hexafluorophosphate and other parameters such as sample pH, temperature, salting-out effect and sample volume on the extraction efficiency were investigated in detail. Four different alkyl chain length ionic liquids ([CnMIM][PF6], n = 4, 6, 7, 8) were tested. The experimental results demonstrated that the alkyl chain length of ionic liquids (ILs) did have an important role on the extraction efficiency. The experimental results indicated that the longer alkyl chain length of ILs resulted in better extraction efficiency. Among the four ILs, 1-octyl-3-methylimidazolium hexafluorophosphate [C8MIM] [PF6] was the best one for extraction of the target analytes. Under the optimized conditions, three pyrethroid insecticides had limits of detection (LOD, S/N = 3) in the range of 0.34∼0.48 μg L-1. The precisions of the proposed method (RSDs, n = 6) with a spiked concentration of 20 μg L-1 were in the range of 2.0∼3.4%. The proposed method was evaluated with real water samples spiked at a concentration of 10 ng mL-1 and good spiked recoveries over the range of 89.2∼102.7% were obtained.
More Related Videos
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Related Concept Videos
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Extraction: Advanced Methods
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: