Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Oil fingerprinting analysis using commercial solid phase extraction (SPE) cartridge and gas chromatography-mass
Zeyu Yang1,2, Chun Yang1, Zhendi Wang1
1Emergencies Science and Technology Section, Environment Canada, Ottawa, ON, Canada. chun.yang@ec.gc.ca.
Abstract:
This study used solid phase extraction (SPE) cartridges for rapid cleanup and fractionation of oil samples in oil fingerprinting analysis. A series of commercially available florisil cartridges, normal phase SPE cartridges, and silica gel/cyanopropyl (SiO2/C3-CN) SPE cartridges was selected for the fractionation of oil into aliphatic and aromatic hydrocarbons. The florisil cartridges and normal phase SPE cartridges can clean up the oil samples but are unable to separate them into two fractions. The SiO2/C3-CN (1 g/0.5 g) SPE cartridge successfully separated oil samples into aliphatic and aromatic fractions by eluting with 4 mL of hexane and 4 mL of dichloromethylene (DCM)/hexane (3 : 1, v:v), respectively. No cross-elution was observed between aliphatic and aromatic fractions when oil loading mass was less than 40 mg on the SiO2/C3-CN SPE cartridge. The relative standard deviation (RSD) of five replicates of SPE-GC-MS analysis of 5 mg of reference oil is 2.8%, 1.2%, and 6.9% for total n-alkanes, polycyclic aromatic hydrocarbons (PAHs), and biomarkers, respectively. The recoveries of six spiked deuterated surrogates were all above 95%. This SPE-GC-MS method was used for the fingerprinting analysis of various crude oils, refined petroleum products, and environmental sediment samples. The characterized target hydrocarbons included n-alkanes, unsubstituted priority PAHs and alkylated homologues, and biomarker terpanes and steranes. The concentration profiles and diagnostic ratios of target compounds are both comparable to those obtained by the conventional silica gel column-GC-MS method.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...