Related Experiment Video
Updated: Dec 8, 2025

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
An online ionic liquid-based microextraction system coupled to electrothermal atomic absorption spectrometry for
Paula Berton1, Rodolfo G Wuilloud1,2
1Analytical Chemistry Research and Development Group (QUIANID), (LISAMEN-CCT-CONICET-Mendoza), Av. Ruiz Leal S/N Parque General San Martín, M 5502 IRA, Mendoza, Argentina. rwuilloud@mendoza-conicet.gob.ar.
Abstract:
In the present work, an ionic liquid (IL) lighter than water was employed as extraction solvent in a dispersive liquid-liquid microextraction (DLLME) methodology. An original flow injection system for online microextraction and preconcentration of cobalt (Co) based on the use of tetradecyl(trihexyl)phosphonium chloride (CYPHOS® IL 101) was designed. Cobalt was complexed with 4-(2-pyridylazo)-resorcinol (PAR) reagent at pH 4.8 and then, the IL-DLLME procedure was developed by dispersing CYPHOS® IL 101 with acetone in an aqueous solution containing Co-PAR complex. Different pyridylazo dyes were evaluated for Co preconcentration in terms of their molecular structure, stability and acid-base equilibrium. Online extraction of Co-PAR into the IL and separation of the dispersed IL enriched phase were accomplished with a microcolumn containing Florisil material. Cobalt was removed from the microcolumn with a 10% (v/v) HNO3 acidified-acetone solution and finally measured by electrothermal atomic absorption spectrometry (ETAAS). The detection limit achieved after preconcentration of 2 mL of sample solution was 8 ng L-1. The precision for 10 replicate determinations at the 1 µg L-1 Co level was 5.1% relative standard deviation (RSD), calculated from the peak heights obtained. The method was successfully applied to Co determination in water samples as well as ophthalmic and parenteral solutions. For the first time, an IL-based microextraction technique was applied for metal determination in these complex samples, where Co recovery varied between 97.9 and 103%.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Related Concept Videos
Ion-Exchange Chromatography
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Extraction: Advanced Methods
Atomic Emission Spectroscopy: Lab