Related Experiment Video
Updated: Dec 8, 2025

Measuring Interactions between Fluorescent Probes and Lignin in Plant Sections by sFLIM Based on Native Autofluorescence
Published on: January 2, 2020
Interference-free determination of and in plant samples using excitation-emission matrix fluorescence based on
Yuan-Na Li1, Hai-Long Wu1, Jin-Fang Nie1
1State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, China. hlwu@hnu.cn.
Abstract:
A sensitive excitation-emission fluorescence method with a second-order calibration strategy is proposed to simultaneously determine abscisic acid (ABA) and gibberellin (GA) contents in extracts of leaves and buds of ginkgo. The methodology is based on the alternating normalization-weighed error (ANWE) and the parallel factor analysis (PARAFAC) algorithms, which make it possible that the ABA and GA concentration can be attained in extract of plants even in the presence of unknown interference from potential interfering matrix contaminants introduced during the simple pretreatment procedure. Satisfactory recoveries were obtained although the excitation and emission profiles of the analytes were heavily overlapped with each other and the background in the extracts. The limits of detection obtained for GA and ABA in leaf samples were 9.6 and 6.9 ng mL-1, respectively, which were in the concentration range (from hundreds to several ng g-1) for GA and ABA in leaves in different periods. Furthermore, in order to investigate the performance of the developed method, some statistical parameters and figures of merit of ANWE and PARAFAC are evaluated. The method proposed lights a new avenue to determine quantitatively phytohormones in extracts of plants with a simple pretreatment procedure, and may hold potential to be extended as a promising alternative for more practical applications in plant growth processes.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
07:58Author Spotlight: Non-Invasive High-Resolution Measurement of Chlorophyll Synthesis During De-Etiolation
Published on: January 12, 2024
Related Concept Videos
Atomic Emission Spectroscopy: Interference
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...