Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Severe stenosis of bioprosthetic valve due to late valve thrombosis
Shruti Hegde1, Youssef Rahban2, Arvind Agnihotri3
1Division of Cardiovascular Medicine, Department of Medicine, St. Elizabeth's Medical Center, Tufts University School of Medicine, Brighton, Massachusetts.
Abstract:
The typical cause of bioprosthetic valve dysfunction over years is calcification of leaflets, pannus formation, or tears due to structural degeneration. Thrombosis is rare as the valves get endothelialized early on, and, hence, anticoagulation is not recommended beyond 6 months after valve replacement. While bioprosthetic valve thrombosis is unusual (0.03% to 0.34%/year), it can be associated with significant mortality and morbidity. Here, we present a case of a middle-aged man with history of bioprosthetic mitral valve who presented with syncopal episode and was referred to us for mitral valve replacement for tentative bioprosthetic valve degeneration and stenosis. However, preoperative work up revealed prosthetic valve thrombosis which was successfully treated with anticoagulation.
More Related Videos
06:59Catheter-based Endovascular Angioplasty for Fibrosing Mediastinitis-associated Pulmonary Vein Stenosis
Published on: August 26, 2025
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Mitral Stenosis I: Introduction
Mitral Stenosis III: Medical Management
Venous Thrombosis I: Introduction
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Valve Prolapse I: Introduction
Mitral Stenosis IV: Nursing Management