Related Experiment Video
Updated: Dec 8, 2025

Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
Effect of Intraocular Pressure on Aerosol Density Generated by Noncontact Tonometer Measurement
Yuan Tang1, Chunchun Li2, Yanyan Chen1,2
1School of Optometry and Ophthalmology.
Precis:
Aerosols generated by a noncontact tonometer (NCT) were quantified. There was a positive correlation between aerosols and intraocular pressure (IOP), and the concentration of aerosols beside the air jet port was the highest.
Purpose:
To investigate the effects of IOP on the aerosol density generated during the use of an NCT and provide references and suggestions for daily protection of ophthalmic medical staff during the coronavirus disease-19 (COVID-19) outbreak.
Objective And Methods:
This cross-sectional clinical trial included 214 eyes of 140 patients from a hospital in Wenzhou city, Zhejiang Province. All subjects' IOPs were measured by an NCT (39 eyes with low IOP, 90 eyes with normal IOP, 37 eyes with moderately high IOP, and 48 eyes with very high IOP) between March 7 and June 17, 2020. The density of particulate matter (PM) 2.5 and PM10 generated during the process of IOP measurement with an NCT was analyzed. IOP values were recorded simultaneously. The aerosols generated during different IOP measurements were plotted in scatter plots.
Results:
PM2.5 was generated more at the air jet port of the tonometer during the process of IOP measurement (H=2.731, P=0.019). Larger quantities of PM2.5 and PM10 were generated when the IOP was higher, and these differences were statistically significant (PM2.5: H=119.476, P<0.001; PM10: H=160.801, P<0.001). Linear correlation analysis with one variable demonstrated that IOP had significantly positive correlations with PM2.5 (r=0.756, P<0.001) and PM10 (r=0.864, P<0.001).
Conclusions:
Aerosols can be generated while using an NCT to measure IOP, and aerosols and IOP are positively correlated. Patients with moderately high IOP or very high IOP tend to generate more aerosols during the IOP measurement. The concentration of aerosols beside the air jet port was the highest.
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Glaucoma: Overview
Assessment of blood pressure in brachial artery(two-step method)

