Melissa Barnett1, Karen G Carrasquillo2, Muriel M Schornack3
1University of California, Davis Eye Center, Sacramento, California.
Significance:
Alignment of the scleral lens haptic with the anterior ocular surface is of critical importance when fitting scleral lenses. The concept of leveraging big-data analysis to drive lens design is explored in this study. This retrospective study evaluated fitting outcomes of a data-driven, quadrant-specific scleral lens design and found that most patients (76%) were successfully fit with this design.
Purpose:
The purpose of this study was to evaluate clinical outcomes with a data-driven, quadrant-specific scleral lens design compared with traditional lens designs.
Methods:
For this multicenter retrospective observational study, A REDCap (Research Electronic Data Capture) survey was distributed to scleral lens practitioners who participated in β testing of a data-driven, quadrant-specific scleral lens design (study lens) between June 1, 2016, and January 31, 2017. Descriptive data were collected, and patient-reported outcomes, visual acuity, and lens design outcomes achieved with the study lens were described.
Results:
Seventy-five patients (85 eyes) were fit with the study lens design between June 2016 and January 2017. Mean patient age was 47 years (range, 17 to 77 years). Forty-six were male, and 29 were female. Seventy-six eyes (89%) were fit for corneal irregularity, whereas nine eyes (11%) were fit for management of ocular surface disease. Compared with habitual correction, 22% more eyes achieved 20/20 or better, and 21% more eyes achieved 20/40 or better. There was also a 60% decrease in the need for midday removal with the study lens. An average of two lenses were manufactured per eye to complete the fitting process.
Conclusions:
Using a data-driven, quadrant-specific scleral lens resulted in visual improvement, a reduced need for midday removal, and an average of two lenses needed to complete the fitting process. Longer-term clinical outcomes and the use of big-data analysis to inform scleral lens design should be further explored.
More Related Videos
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
05:56Scleral Cross-linking Using Riboflavin and Ultraviolet-A Radiation for Prevention of Axial Myopia in a Rabbit Model
Published on: April 3, 2016
Related Concept Videos
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...