Non-Destructive Quality Assessment of Tomato Paste by Using Portable Mid-Infrared Spectroscopy and Multivariate
Didem Peren Aykas1,2, Karla Rodrigues Borba3, Luis E Rodriguez-Saona1
1Department of Food Science and Technology, The Ohio State University, 100 Parker Food Science and Technology Building, 2015 Fyffe Road, Columbus, OH 43210, USA.
Abstract:
This research aims to provide simultaneous predictions of tomato paste's multiple quality traits without any sample preparation by using a field-deployable portable infrared spectrometer. A total of 1843 tomato paste samples were supplied by four different leading tomato processors in California, USA, over the tomato seasons of 2015, 2016, 2017, and 2019. The reference levels of quality traits including, natural tomato soluble solids (NTSS), pH, Bostwick consistency, titratable acidity (TA), serum viscosity, lycopene, glucose, fructose, ascorbic acid, and citric acid were determined by official methods. A portable FT-IR spectrometer with a triple-reflection diamond ATR sampling system was used to directly collect mid-infrared spectra. The calibration and external validation models were developed by using partial least square regression (PLSR). The evaluation of models was conducted on a randomly selected external validation set. A high correlation (RCV = 0.85-0.99) between the reference values and FT-IR predicted values was observed from PLSR models. The standard errors of prediction were low (SEP = 0.04-35.11), and good predictive performances (RPD = 1.8-7.3) were achieved. Proposed FT-IR technology can be ideal for routine in-plant assessment of the tomato paste quality that would provide the tomato processors with accurate results in shorter time and lower cost.
More Related Videos
06:50O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
Qualitative Analysis
There are two main approaches to qualitative analysis:...
Applications of IR Spectroscopy: Overview
