Related Experiment Video
Updated: Dec 8, 2025

Implementation of Portable Emissions Measurement Systems PEMS for the Real-driving Emissions RDE Regulation in Europe
Published on: December 4, 2016
Patch test results with the European baseline series and additions thereof in the ESSCA network, 2015-2018
Wolfgang Uter1, Andrea Bauer2, Anna Belloni Fortina3
1Department of Medical Informatics, Biometry and Epidemiology, University of Erlangen/Nürnberg, Erlangen, Germany.
Background:
Clinical surveillance of the prevalence of contact allergy in consecutively patch tested patients is a proven instrument to continually assess the importance of contact allergens (haptens) assembled in a baseline series.
Objectives:
To present current results from the European Surveillance System on Contact Allergies, including 13 countries represented by 1 to 11 departments.
Methods:
Anonymized or pseudonymized patch test and clinical data from various data capture systems used locally or nationally as transferred to the Erlangen data centre were pooled and descriptively analysed after quality control.
Results:
In the 4 years (2015-2018), data from 51 914 patients patch tested with the European baseline series (EBS) of contact allergens were analysed. Contact allergy to nickel was most frequent (17.6% positive), followed by contact allergy to fragrance mix I (6.9%), methylisothiazolinone (MI; 6.2%), and Myroxylon pereirae resin (balsam of Peru; 5.8%).
Conclusions:
While the prevalence of MI contact allergy decreased substantially following regulatory intervention, the persistently high levels of allergy to metals, fragrances, other preservatives, and rubber chemicals point to problems needing further research and, potentially, preventive efforts. Results with national additions to the baseline series provide important information on substances possibly to be considered for inclusion in the EBS.
More Related Videos
09:07Author Spotlight: Accelerating Diagnostic Accuracy with Direct Identification of Gram-Negatives from Blood Culture Bottles
Published on: May 24, 2024
16:02Demonstration of the Sequence Alignment to Predict Across Species Susceptibility Tool for Rapid Assessment of Protein Conservation
Published on: February 10, 2023
Related Concept Videos
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...