Novel noninvasive estimation of mixed venous oxygen saturation by echocardiography and expired gas analysis
Takeshi Onoue1, Mai Iwataki1, Masaru Araki1
1Second Department of Internal Medicine, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan.
Abstract:
Mixed venous oxygen (O2) saturation ([Formula: see text]) is an important measure for evaluating the sufficiency of cardiac output (CO) relative to whole body O2 consumption (V̇o2), while clinical use is limited to the required invasive catheterization. According to Fick's equation, V̇o2 (mL/min) = CO (L/min) × Hb (g/dL) × 1.36 (mL/g) × ([Formula: see text] - [Formula: see text])/10 (Hb = hemoglobin concentration, [Formula: see text] = arterial blood O2 saturation). Because V̇o2, CO, Hb, and [Formula: see text] can be measured noninvasively with expired gas analysis, echocardiography, a simple blood test, and percutaneous O2 saturation, respectively, [Formula: see text] can be calculated noninvasively. We hypothesized that noninvasively calculated [Formula: see text] shows a significant correlation and agrees well with invasively measured [Formula: see text]. In 47 patients (29 men; mean age, 70 ± 12 yr) who underwent right heart catheterization, [Formula: see text] was directly measured by sampling pulmonary artery blood. Noninvasively calculated [Formula: see text] was also obtained by the method described above. The calculated [Formula: see text] was significantly correlated with the measured [Formula: see text] (r = 0.79, P < 0.001) and was significantly smaller than the measured [Formula: see text] (70 ± 5.1 vs. 72.1 ± 4.9%, P < 0.001). Bias at [Formula: see text] was -2.2% (95% confidence interval, -3.2 to -1.1%) with limits of agreement from -9.5 to 5.2%, demonstrating acceptable agreement. The optimal cutoff value of calculated [Formula: see text] was 69% for reduced measured [Formula: see text] < 70% with an area under the curve of 0.94. Reduced calculated [Formula: see text] < 69% indicated a sensitivity of 92.9% and a specificity of 90.9% for reduced measured [Formula: see text] < 70%. Noninvasive [Formula: see text] calculated from echocardiography, expired gas analysis, percutaneous arterial blood O2 saturation, and hemoglobin level significantly correlated and agreed well with direct [Formula: see text] measured by catheterization. This novel method allows for practical evaluation of [Formula: see text] to assess the sufficiency of CO according to whole body metabolism.NEW & NOTEWORTHY Clinical use of mixed venous oxygen saturation ([Formula: see text]) is limited to the required invasive procedure. With Fick's equation, expired gas analysis, echocardiography, simple blood tests, and percutaneous oxygen saturation, [Formula: see text] can be calculated noninvasively. We hypothesized that noninvasively calculated [Formula: see text] shows a significant correlation and agrees well with invasively measured [Formula: see text]. The present study examined the relationship between measured [Formula: see text] and calculated [Formula: see text] in patients who underwent right heart catheterization and demonstrated acceptable agreement. This novel method can expand the indication of evaluating [Formula: see text].
More Related Videos
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
