Related Experiment Video
Updated: Dec 8, 2025

Use of Rabbit Eyes in Pharmacokinetic Studies of Intraocular Drugs
Published on: July 23, 2016
Population Pharmacokinetic Modeling of Vancomycin in Thai Patients With Heterogeneous and Unstable Renal Function
Siriluk Jaisue1, Cholatip Pongsakul2, David Z D'Argenio3
1Division of Clinical Pharmacy, Faculty of Pharmaceutical Sciences, Khon Kaen University.
Background:
Vancomycin is widely used to treat gram-positive bacterial infections. However, given significant interpatient variability in its pharmacokinetics, maintaining plasma concentrations is difficult within its characteristically narrow therapeutic window. This is especially challenging in patients with unstable renal function. Thus, the aim of this study was to develop a population pharmacokinetic model for vancomycin that is suitable for Thai patients with variable renal functions, including those with unstable renal function.
Methods:
Data from 213 patients, including 564 blood samples, were retrospectively collected; approximately 70% patients exhibited unstable renal function during vancomycin treatment. The model building group was randomly assigned 108 patients and the remaining 33 patients comprised the validation group. A population pharmacokinetic model was developed that incorporated drug clearance (CL) as a function of time-varying creatine clearance (CrCL). The predictive ability of the resulting population model was evaluated using the validation data set, including its ability to forecast serum concentrations within a Bayesian feedback algorithm.
Results:
A 2-compartment model with drug CL values that changed with time-varying CrCL adequately described vancomycin pharmacokinetics in the evaluated heterogeneous patient population with unstable renal function. Vancomycin CL was related to time-varying CrCL as follows: CL (t) = 0.11 + 0.021 × CrCL (t) (CrCL <120 mL/min. Using the population model, Bayesian estimation with at least one measured serum concentration resulted in a forecasting error of small bias (-2.4%) and adequate precision (31.5%).
Conclusions:
In hospitals with a high incidence of unstable renal function, incorporating time-varying CrCL with Bayesian estimation and at least one measured drug concentration, along with frequent CrCL monitoring, improves the predictive performance of therapeutic drug monitoring of vancomycin.
More Related Videos
09:17A Robust Pneumonia Model in Immunocompetent Rodents to Evaluate Antibacterial Efficacy against S. pneumoniae, H. influenzae, K. pneumoniae, P. aeruginosa or A. baumannii
Published on: January 2, 2017
11:17Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
Related Concept Videos
Estimation of k and VD of Aminoglycosides
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Pharmacokinetics in Pediatric Patients: Drug Excretion
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Pharmacokinetics in Geriatric Patients: Effect of Age on Drug Excretion
Dosage Regimens: Partial Pharmacokinetic Parameters