Related Experiment Video
Updated: Dec 8, 2025

Predicting Amputation using Local Circulating Mononuclear Progenitor Cells in Angioplasty-treated Patients with Critical Limb Ischemia
Published on: September 22, 2020
Real-World Experience With a Paclitaxel-Coated Balloon in Critical Limb Ischemia: 24-Month Subgroup Outcomes of
Marianne Brodmann1, Matej Moscovic2, John Chaw Chian Wang3
1Division of Angiology, Medical University Graz, Graz, Austria.
Objectives:
The aim of the BIOLUX P-III (A Prospective, International, Multi-Centre, Post-Market All-Comers Registry to Assess the Clinical Performance of the Passeo-18 Lux Paclitaxel Releasing Balloon Catheter in Infrainguinal Arteries - III) registry was to collect real-world data on the Passeo-18 Lux paclitaxel-coated balloon.
Background:
Critical limb ischemia (CLI) is a severe condition associated with high morbidity and mortality. Prospective data are needed to provide further insights on drug-eluting devices.
Methods:
BIOLUX P-III is a prospective, post-market, all-comers registry assessing the safety and performance of the Passeo-18 Lux. Clinical information was collected at 6, 12, and 24 months. The authors report 24-month outcomes of the CLI subgroup with patients in Rutherford classes 4 to 6.
Results:
The CLI subgroup included 328 patients with 422 lesions. Patients were 71.1 ± 10.5 years of age, and 61.0% had diabetes. Femoropopliteal lesions were present in 53.8% (n = 227), below-the-knee lesions were present in 27.0% (n = 114), and lesions were moderate or heavily calcified in 45.0% (n = 190). Major adverse events, defined as 30-day device- or procedure-related mortality, major target limb amputation, and clinically driven target lesion revascularization, occurred in 9.8% of patients through 6 months, in 14.9% through 12 months, and in 19.4% through 24 months. Clinically driven target lesion revascularization occurred in 4.4%, 8.5%, and 12.1%, major amputation in 4.9%, 5.2%, and 6.1%, and mortality in 8.1%, 11.1%, and 20.1%, respectively. Predictors of mortality were age ≥75 years and higher Trans-Atlantic Inter-Society Consensus Document on Management of Peripheral Arterial Disease class, and higher Rutherford class was associated with increased mortality and amputation rates.
Conclusions:
In a large, multimorbid patient population with complex lesions and CLI, the safety and performance of the Passeo-18 Lux paclitaxel-coated balloon has been confirmed, with low rates of major amputation and target lesion revascularization.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
09:38Minimally Invasive Isolated Limb Perfusion (MI-ILP) for Locally Advanced Melanomas and Sarcomas of the Extremity
Published on: January 31, 2025
Related Concept Videos
Peripheral Artery Disease III: Interprofessional Care
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation