Related Experiment Video
Updated: Dec 8, 2025

Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients
Published on: March 29, 2022
Accuracy of Artificial Intelligence Formulas and Axial Length Adjustments for Highly Myopic Eyes
Huanhuan Cheng1, Li Wang2, Jack X Kane3
1State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China; Department of Ophthalmology, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China.
Purpose:
To compare the accuracy of artificial intelligence formulas (Kane formula and Radial Basis Function [RBF] 2.0) and other formulas, including the original and modified Wang-Koch (MWK) adjustment formulas for Holladay 1 (H1-MWK) and SRK/T (SRK/T-WK and SRK/T-MWK), the Barrett Universal II (BUII), the emmetropia-verifying optical (EVO), and the Haigis equation in highly myopic eyes.
Design:
Retrospective consecutive case-series study.
Methods:
A total of 370 eyes with an axial length (AL) ≥26.0 mm of 370 patients were enrolled, and subgroup analyses was performed based on ALs. The median absolute error (MedAE), the percentages of eyes with hyperopic outcome and within ±0.25 diopters (D), ±0.50 D, and ±1.00 D of prediction error were determined.
Results:
Overall, the Kane equation had the lowest MedAE (0.26 D), followed by H1-WK (0.27 D) and H1-MWK (0.28 D). There were no significant differences in MedAE among the Kane equation, the RBF 2.0, the BUII, the H1-MWK, and the H1-WK, whereas the Kane equation had a significantly lower MedAE than EVO (P < .001), SRK/T-MWK (P = .001), SRK/T-WK (P = .006), and Haigis (P < .001). In extremely myopic eyes with an AL ≥30.0 mm (n = 115), the Kane equation had a significantly lower MedAE than the RBF 2.0 (P = .001), the EVO (P = .019), the BUII (P = .013), and the Haigis method (P = .005), whereas no significant differences were found among the Kane, H1-MWK, and H1-WK equations.
Conclusions:
The Kane equation was comparable to RBF 2.0, BUII, H1-MWK, and H1-WK in highly myopic eyes and was better than RBF 2.0 and BUII in extremely myopic eyes. The Kane, H1-MWK, and H1-WK methods were equally accurate in eyes with high to extreme myopia.
Related Concept Videos
Focusing of Light in the Eye
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Adjusting a Traverse