Related Experiment Video
Updated: Dec 8, 2025

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Incidental Findings of Pulmonary and Hilar Malignancy by Low-Resolution Computed Tomography Used in Myocardial
Robert T Tung1, Johannes Heyns1, Lynne Dryer1
1is a Cardiologist, is a Radiologist, and is a Radiology and Cardiology Nurse Practitioner; all at the US Department of Veterans Affairs Eastern Kansas Healthcare System in Topeka.
Background:
Low dose, low-resolution computed tomography (CT) is used for attenuation correction to improve the quality of single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). Because of its low resolution, these CT images are considered non-diagnostic and are not routinely or uniformly reviewed or interpreted by a cardiologist. On the other hand, low-dose CT has been used for lung cancer screening to reduce lung cancer mortality and is recommended for annual screening of high-risk patients by the US Preventive Services Task Force.
Methods:
Siemens Symbia Intevo Excel SPECT/CT scanners, used primarily for cardiac MPI, were used in the study. The study was intended to report incidental findings of pulmonary and hilar malignancy detected by these CT images during cardiac evaluation. It included 1,098 consecutive patients who had SPECT MPI from September 1, 2017 to August 31, 2018. When suspicious pulmonary nodules or abnormalities were identified, primary care providers were notified of the findings and recommendations for further evaluation.
Results:
Five patients were found to have lung cancer (all male with substantial smoking history, aged 64-75 years), 1 had mantle cell lymphoma. Six of 1,098 (0.55%) patients were found to have incidental pulmonary/hilar malignancy, which is comparable to the yield (0.65%/year) of detecting lung cancer using low-dose CT for screening in The National Lung Screening Trial.
Conclusions:
Routine review and report of incidental findings on low-resolution CT during cardiac MPI by physicians skilled in CT interpretation is necessary to identify incidental but clinically important findings, including malignancies.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Mitral Stenosis II: Clinical features and Diagnostic Tests

