Impact of prosthesis-patient mismatch on early and late outcomes after mitral valve replacement: a meta-analysis

Meng-Wei Tan1, Yi-Fan Bai1, Xiao-Hong Liu1

  • 1Department of Cardiothoracic Surgery, Changhai Hospital, Naval Military Medical University (The Second Military Medical University), Shanghai, China.

Abstract

Insights

Prosthesis-patient mismatch (PPM) after mitral valve replacement (MVR) is linked to worse outcomes. Avoiding severe PPM is crucial, as its negative impact increases with severity, affecting hemodynamics and long-term survival.

Area of Science:

  • Cardiology
  • Cardiac Surgery
  • Biomedical Engineering

Background:

  • Prognostic significance of prosthesis-patient mismatch (PPM) after mitral valve replacement (MVR) is uncertain due to limited and conflicting studies.
  • This meta-analysis aimed to clarify the early and late prognostic implications of significant mitral PPM.

Purpose of the Study:

  • To evaluate the impact of mitral prosthesis-patient mismatch (PPM) on postoperative hemodynamics and patient prognosis.
  • To assess the relationship between PPM severity and clinical outcomes after mitral valve replacement (MVR).

Main Methods:

  • Systematic literature search of major databases (PubMed, EMBASE, Cochrane, ClinicalTrials.gov).
  • Meta-analysis of 19 cohort studies (9302 patients) comparing outcomes between patients with and without significant mitral PPM.
  • Sensitivity analyses, meta-regression, and subgroup analyses were used to assess robustness and heterogeneity.

Main Results:

  • Mitral PPM was associated with poorer postoperative hemodynamics, including higher transprosthetic pressure gradients and pulmonary artery pressures.
  • Patients with mitral PPM exhibited higher 30-day and long-term mortality, increased congestive heart failure prevalence, and less improvement in NYHA class.
  • The negative impact of PPM was severity-dependent, with severe PPM leading to worse outcomes.

Conclusions:

  • Mitral prosthesis-patient mismatch (PPM) significantly worsens postoperative hemodynamics and both early and late patient prognosis.
  • Avoiding severe mitral PPM is critical to mitigate its detrimental effects on patient outcomes after mitral valve replacement (MVR).
  • The severity of PPM directly correlates with the degree of adverse hemodynamic and prognostic impact.

Related Concept Videos

Mitral Valve Prolapse I: Introduction01:27

Mitral Valve Prolapse I: Introduction

IntroductionThe mitral valve, one of the heart's four valves, regulates blood flow. These valves have flaps that open and close to direct blood properly through the heart and body. During each heartbeat, the flaps open for blood to pass through and seal shut to prevent backflow. Specifically, the mitral valve opens to allow blood flow from the heart's upper left chamber to the lower left chamber. It then closes securely as the lower left chamber contracts to pump blood to the body, preventing...
206
Mitral Valve Prolapse II: Assessment and Management01:22

Mitral Valve Prolapse II: Assessment and Management

IntroductionA range of clinical features characterizes Mitral Valve Prolapse (MVP), but it is important to note that many individuals with MVP are asymptomatic and may remain so throughout their lives. For those who do exhibit symptoms, the following are the key clinical features:Palpitations: This is a common symptom where individuals feel an irregular or rapid heartbeat. Palpitations in MVP are often due to arrhythmias such as premature ventricular contractions or supraventricular...
219
Mitral Stenosis III: Medical Management01:26

Mitral Stenosis III: Medical Management

Mitral stenosis, a condition marked by the narrowing of the mitral valve, necessitates an integrated approach for effective management. This approach includes preventative measures, medical therapy, and surgical interventions to reduce symptoms and prevent complications.PreventionPrevention of mitral stenosis primarily focuses on reducing the incidence of bacterial infections, particularly streptococcal infections, which can lead to rheumatic fever and subsequent valvular damage. Timely...
149
Mitral Stenosis I: Introduction01:22

Mitral Stenosis I: Introduction

Mitral Valve Stenosis (MVS) is a heart condition where the mitral valve narrows, impeding blood circulation from the left atrium to the left ventricle. The etiology and pathophysiology of this condition are multifaceted, leading to a cascade of cardiovascular complications.Causes of Mitral Valve StenosisRheumatic Heart Disease: It is the main cause of mitral valve stenosis, particularly in developing nations. This condition arises from rheumatic fever, an inflammatory illness resulting from...
208
Mitral Stenosis II: Clinical features and Diagnostic Tests01:23

Mitral Stenosis II: Clinical features and Diagnostic Tests

Mitral stenosis is a heart condition in which the mitral valve, which allows blood to flow from the left atrium to the left ventricle, becomes narrowed or stenotic. This narrowing hinders blood flow and leads to clinical symptoms requiring specific medical evaluations and management strategies. The following overview outlines the clinical symptoms, assessments, diagnostic findings, prevention methods, and treatments for mitral stenosis.Clinical ManifestationsDyspnea (shortness of breath): This...
117
Mitral Valve Prolapse III: Nursing Management01:19

Mitral Valve Prolapse III: Nursing Management

The nursing management of Mitral Valve Prolapse, or MVP, centers around patient education, symptom monitoring, and lifestyle modifications.Patient Education on MVP Diagnosis and Heredity: Nurses should provide comprehensive education about MVP, a condition where the mitral valve does not close appropriately during heartbeats. This education often includes the condition's pathophysiology, symptoms, and potential complications, like arrhythmias or mitral regurgitation. Though not fully...
152