Related Experiment Video
Updated: Dec 8, 2025

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Absorbed dose distributions from beta-decaying radionuclides: Experimental validation of Monte Carlo tools for
Ashok Tiwari1,2, John Sunderland1,2, Stephen A Graves1,3
1Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Dr., Iowa City, IA, 52242-1077, USA.
Purpose:
This study aims to experimentally validate the Monte Carlo generated absorbed doses from the beta particles emitted by 90 Y and 177 Lu using radiochromic EBT3 film-based dosimetry.
Methods:
Line sources of 90 Y and 177 Lu were inserted longitudinally through blocks of low-density polyethylene and tissue-equivalent slabs of cortical bone and lung equivalent plastics. Radiochromic film (Gafchromic EBT3) was laser cut to accommodate orthogonal line sources of radioactivity, and the film was sandwiched intimately between the rectangular blocks to achieve charged particle equilibrium. Line sources consisted of plastic capillary tube of length (13 ± 0.1) cm, with 0.42-mm inner diameter and a wall thickness of 0.21 mm. 90 Y line sources were prepared from a solution of dissolved 90 Y resin microspheres. 177 Lu line sources were prepared from an aliquot of 177 Lu-DOTATATE. Film exposures were conducted for durations ranging from 10 min to 38 h. Radiochromic film calibration was performed by irradiation with 6-MV-bremsstrahlung x rays from a calibrated linear accelerator, in accordance with literature recommendations. Experimental geometries were precisely simulated within the GATE Monte Carlo toolkit, which has previously been used for the generation of dose point kernels.
Results:
The mean percentage difference between measured and simulated absorbed doses were 5.04% and 7.21% for 90 Y and 177 Lu beta absorbed dose in the range of (0.1-10) Gy. Additionally, 1D gamma analysis using a local 10%/1 mm gamma criterion was performed to compare the absorbed dose distributions. The percentage of measurement points passing the gamma criterion, averaged over all tests, was 93.5%.
Conclusions:
We report the experimental validation of Monte Carlo derived beta absorbed dose distributions for 90 Y and 177 Lu, solidifying the validity of using Monte Carlo-based methods for estimating absorbed dose from beta emitters. Overall, excellent agreement was observed between the experimental beta absorbed doses in the linear region of the radiochromic film and the GATE Monte Carlo simulations demonstrating that radiochromic film dosimetry has sufficient sensitivity and spatial resolution to be used as a tool for measuring beta decay absorbed dose distributions.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Biological Effects of Radiation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Isotopes and Radioisotopes
An isotope containing...
Types of Radioactivity
Alpha (α) decay is the emission of an α particle from the nucleus. For example, polonium-210 undergoes α decay: