Electrophysiological assessment of temporal envelope processing in cochlear implant users
Robin Gransier1, Robert P Carlyon2, Jan Wouters3
1Department of Neurosciences, KU Leuven, ExpORL, Herestraat 49, Box 721, 3000, Leuven, Belgium. robin.gransier@kuleuven.be.
We developed a new EEG method to remove stimulation artifacts in cochlear implant (CI) users. This technique successfully measured neural responses, showing the 40-Hz auditory steady-state response (eASSR) is a promising clinical tool for assessing speech encoding.
Area of Science:
- Neuroscience
- Biomedical Engineering
- Audiology
Background:
- Cochlear implant (CI) users require accurate encoding of temporal envelope modulations (TEMs) for speech comprehension.
- Clinical success in CI users is linked to the fidelity of neural ensemble encoding of TEMs.
- Non-invasive electroencephalography (EEG) could offer a method to assess this encoding, but is challenged by large stimulation artifacts.
Purpose of the Study:
- To develop and validate an EEG method for artifact-free measurement of neural responses to electrical stimulation in CI users.
- To assess the feasibility of using EEG measures to evaluate the encoding of temporal envelope modulations (TEMs) in CI users.
- To compare the sensitivity of the 40-Hz electrically evoked auditory steady-state response (eASSR) and electrically evoked auditory change complex (eACC) to modulation depth.
Main Methods:
- Utilized a custom-built, high-sample-rate EEG system to precisely capture stimulation artifacts.
- Employed linear interpolation to remove artifacts, enabling the isolation of neural responses.
- Measured 40-Hz eASSR and eACC in ten adult CI users using amplitude-modulated pulse trains at various modulation depths.
Main Results:
- Successfully recorded artifact-free 40-Hz eASSRs and eACCs in CI users.
- Demonstrated that the 40-Hz eASSR exhibited significant responses even at shallow modulation depths.
- Observed that the eACC was less responsive at shallower modulation depths compared to the 40-Hz eASSR.
Conclusions:
- The 40-Hz eASSR is a robust and artifact-free measure of neural encoding in CI users.
- The 40-Hz eASSR shows potential as a clinically viable objective tool for assessing TEM encoding.
- This method could aid clinicians in optimizing CI performance by identifying and potentially disabling non-responsive electrodes.