Contrast-Enhanced Ultrasound Versus Doppler Ultrasound for Detection of Early Vascular Complications of Pancreas
Jordan Swensson1, Danielle Hill1, Temel Tirkes1
1Department of Radiology and Imaging Sciences, Indiana University School of Medicine, 550 N University Blvd Rm 0663, Indianapolis, IN 46202.
Abstract:
OBJECTIVE. The purpose of this study is to compare conventional duplex ultrasound and contrast-enhanced ultrasound (CEUS) for identifying vascular abnormalities in pancreas allografts in the immediate posttransplant setting. Identification of pancreas allografts at risk of failure may impact patient care because early intervention for vascular insufficiency can lead to graft salvage. MATERIALS AND METHODS. Two radiologists who were blinded to patient outcomes performed a retrospective analysis of the postoperative Doppler ultrasound and CEUS images of 34 pancreas grafts from transplants performed between 2017 and 2019. A total of 28 patients who did not require surgical reexploration were considered the control group. Six patients had surgically proven arterial or venous abnormalities on surgical reexploration. Each radiologist scored grafts as having normal or abnormal vascularity on the basis of image sets obtained using Doppler ultrasound only and CEUS only. Comparisons of both the diagnostic performance of each modality and interobserver agreement were performed. RESULTS. Both readers showed that CEUS had increased sensitivity for detecting vascular abnormalities (83.3% for both readers) compared with Doppler ultrasound (66.7% and 50.0%). For both readers, the specificity of CEUS was similar to that of Doppler imaging (81.6% and 78.9% for reader 1 and reader 2 versus 76.3% and 84.2% for reader 1 and reader 2). For both readers, the negative predictive value of CEUS was higher than that of Doppler ultrasound (96.9% and 96.8% for reader 1 and reader 2 versus 93.5% and 91.4% for reader 1 and reader 2). Interobserver agreement was higher for CEUS than for Doppler ultrasound (κ = 0.54 vs κ = 0.28). CONCLUSION. CEUS may provide radiologists and surgeons with a means of timely and effective evaluation of pancreas graft perfusion after surgery, and it may help identify grafts that could benefit from surgical salvage.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...