Related Experiment Video
Updated: Dec 8, 2025

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Objective evaluation of immediate reading skin prick test applying image planimetric and reaction thermometry
Ana Laura Mendes Almeida1, Edson Luiz Pontes Perger1, Ramon Hernany Martins Gomes2
1Medical School, Sao Paulo State University (UNESP), Prof. Mário Rubens Guimarães Montenegro Avenue, s/n, Botucatu, SP, Brazil.
Abstract:
The skin prick test is used to diagnose patients' sensitization to antigens through a mediated IgE response. It is a practical and quick exam, but its diagnosis depends on instruments for measuring the allergic response and observer's interpretation. The conventional method for inferring about the allergic reaction is performed from the dimensions of the wheals, which are measured using a ruler or a caliper. To make this diagnosis less dependent on human interpretation, the present study proposes two alternative methods to infer about the allergic reaction: computational determination of the wheal area and a study of the temperature variation of the patient's skin in the puncture region. For this purpose, prick test using histamine was performed on 20 patients randomly selected. The areas were determined by the conventional method using the dimensions of the wheals measured with a digital caliper 30 min after the puncture. The wheal areas were also determined by a Python algorithm using photographs of the puncture region obtained with a smartphone. A variable named circularity deviation was also determined for each analyzed wheal. The temperature variation was monitored using an infrared temperature sensor, which collected temperature data for 30 min. All results were statistically compared or correlated. The results showed that the computational method to infer the wheal areas did not differ significantly from the areas determined by the conventional method (p-value = 0.07585). Temperature monitoring revealed that there was a consistent temperature increase in the first minutes after the puncture, followed by stabilization, so that the data could be adjusted by a logistic equation (R2 = 0.96). This adjustment showed that the optimal time to measure the temperature is 800 s after the puncture, when the temperature stabilization occurs. The results have also shown that this temperature stabilization has a significant positive correlation with wheal area (p-value = 0.0015). Thus, we concluded that the proposed computational method is more accurate to infer the wheal area when compared to the traditional method, and that the temperature may be used as an alternative parameter to infer about the allergic reaction.
More Related Videos
04:34Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
06:31Precision Implementation of Minimal Erythema Dose MED Testing to Assess Individual Variation in Human Inflammatory Response
Published on: October 3, 2019
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...