Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Dose Size and Dosing Frequency: Determination Methods01:21

Dose Size and Dosing Frequency: Determination Methods

136
Determining the optimal dose size and dosing frequency in pharmacotherapy is crucial for achieving therapeutic effectiveness while minimizing adverse effects. This article explores the methodologies employed in determining these parameters, focusing on their significance and interplay to tailor dosing regimens.Dose Size: Dose size refers to the amount of a drug administered in a single dose. It is determined based on the drug's pharmacodynamics and pharmacokinetics properties and...
136
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses01:25

Determination of Multiple Dosing Parameters: Loading and Maintenance Doses

110
A loading dose is an essential pharmacological strategy to rapidly achieve the target plasma drug concentration necessary for an immediate therapeutic effect. This approach is especially critical for drugs characterized by slow absorption or extended half-lives, where delaying therapeutic plasma levels could compromise treatment outcomes. By administering a loading dose, clinicians ensure a prompt onset of drug action, even for agents with complex pharmacokinetic profiles.Achieving steady-state...
110
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations01:15

Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations

115
Gentamicin, an aminoglycoside antibiotic, is commonly administered via intermittent intravenous infusion to treat severe infections. An intermittent one-hour infusion of gentamicin, administered at eight-hour intervals, allows for precise control of plasma drug concentrations, minimizing toxicity while ensuring therapeutic efficacy. Pharmacokinetic principles govern the dynamics of plasma concentrations and can be mathematically described using specific equations.The plasma drug concentration...
115
Dosage Regimen: Individualization01:24

Dosage Regimen: Individualization

96
Individualization in dosing regimens is the customization of medication doses for individual patients. Its necessity arises from the goal of maximizing therapeutic benefits while minimizing risks. This approach is pivotal because human responses to drugs can vary widely; what is effective for one person may be inadequate or excessive for another. Interpatient (intersubject) variability refers to differences in drug responses between individuals, while intrapatient (intrasubject) variability...
96
Radiation: Applications01:17

Radiation: Applications

1.6K
The average temperature of Earth is the subject of much current discussion. Earth is in radiative contact with both the Sun and dark space; it receives almost all its energy from the radiation of the Sun and reflects some of it into outer space. Dark space is very cold, about 3 K, so Earth radiates energy into it. For instance, heat transfer occurs from soil and grasses, the rate of which can be so rapid that frost can occur on clear summer evenings, even in warm latitudes.
The average...
1.6K
Dosage Regimens: Designs and Approaches01:28

Dosage Regimens: Designs and Approaches

163
Designing a dosage regimen, which refers to the manner of drug administration, is a complex process involving the selection of drug dose, route, and frequency. This process is underpinned by pharmacokinetic parameters derived from tests and population averages. These parameters are then tailored to patient-specific variables such as diagnosis, demographics, and allergy status. Once therapy commences, therapeutic response monitoring is critical and achieved through clinical and physical...
163

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Parameter Selection in Coupled Dynamical Systems for Tomographic Image Reconstruction.

Journal of imaging·2026
Same author

Iterative Tomographic Image Reconstruction Algorithm Based on Extended Power Divergence by Dynamic Parameter Tuning.

Journal of imaging·2024
Same author

Block-Iterative Reconstruction from Dynamically Selected Sparse Projection Views Using Extended Power-Divergence Measure.

Entropy (Basel, Switzerland)·2022
Same author

Noise-Robust Image Reconstruction Based on Minimizing Extended Class of Power-Divergence Measures.

Entropy (Basel, Switzerland)·2021

Related Experiment Video

Updated: Dec 8, 2025

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
08:34

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies

Published on: February 6, 2019

20.8K

Intensity-Modulated Radiation Therapy Optimization for Acceptable and Remaining-One Unacceptable Dose-Volume and

Ryosei Nakada1, Omar M Abou Al-Ola2, Tetsuya Yoshinaga3

  • 1Graduate School of Health Sciences, Tokushima University, 3-18-15 Kuramoto, Tokushima 770-8509, Japan.

Computational and Mathematical Methods in Medicine
|September 23, 2020
PubMed
Summary
This summary is machine-generated.

This study introduces a new continuous dynamical method for intensity-modulated radiation therapy (IMRT) optimization. The approach effectively handles dose constraints for improved treatment planning and achieves near-optimal solutions even for complex cases.

More Related Videos

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
08:25

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System

Published on: April 11, 2018

15.7K
Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
08:17

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy

Published on: June 7, 2015

16.1K

Related Experiment Videos

Last Updated: Dec 8, 2025

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
08:34

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies

Published on: February 6, 2019

20.8K
Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
08:25

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System

Published on: April 11, 2018

15.7K
Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
08:17

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy

Published on: June 7, 2015

16.1K

Area of Science:

  • Medical Physics
  • Computational Biology
  • Radiation Oncology

Background:

  • Intensity-modulated radiation therapy (IMRT) planning involves complex optimization to meet various dose constraints.
  • Conventional IMRT planning methods may face challenges in simultaneously satisfying diverse dose-volume and mean-dose objectives.
  • The discrepancy between optimization objectives and evaluation metrics can complicate treatment planning.

Purpose of the Study:

  • To develop a novel iterative algorithm for IMRT optimization using continuous dynamical methods.
  • To directly incorporate dose-volume and mean-dose constraints into the IMRT planning process.
  • To address the issue of differing objectives and evaluations in conventional IMRT planning.

Main Methods:

  • Derivation of an iterative algorithm from a continuous-time dynamical system.
  • Application of Lyapunov stability theorem to prove convergence to a desired IMRT plan.
  • Introduction of the concept of "acceptable" planning to ensure feasible solutions.
  • Development of a procedure for obtaining near-optimal solutions for unacceptable planning scenarios.

Main Results:

  • The proposed method successfully handles both dose-volume and mean-dose constraints directly.
  • Theoretical convergence to a stable equilibrium corresponding to the desired IMRT plan is demonstrated.
  • The method resolves the objective-evaluation discrepancy in conventional planning.
  • Numerical experiments confirm the approach's effectiveness for both acceptable and unacceptable planning.

Conclusions:

  • Continuous dynamical methods offer a robust approach for IMRT optimization.
  • The novel algorithm provides a unified framework for handling multiple dose constraints.
  • This method enhances treatment planning by ensuring feasibility and achieving near-optimal outcomes for challenging cases.