Preclinical Development of Near-Infrared-Labeled CD38-Targeted Daratumumab for Optical Imaging of CD38 in Multiple

Nicholas Cho1,2, Sooah Ko2, Monica Shokeen3,4,5

  • 1Department of Radiology, Washington University School of Medicine, St. Louis, MO, 63110, USA.

Abstract

Insights

Near-infrared fluorescence imaging using DARA-IRDye800 allows for whole-body monitoring of CD38 expression in preclinical multiple myeloma. This novel method effectively visualizes tumor burden and treatment response, offering advantages over traditional methods.

Area of Science:

  • Biomedical imaging
  • Molecular imaging
  • Cancer research

Background:

  • Cluster of differentiation 38 (CD38) is a key therapeutic target in multiple myeloma (MM).
  • Current preclinical methods for evaluating CD38 expression lack whole-body information and can be cumbersome.
  • Existing in vivo imaging techniques have limitations in observing molecular interactions over time.

Purpose of the Study:

  • To demonstrate the utility of near-infrared (NIR) fluorescence imaging for monitoring CD38 expression in preclinical MM.
  • To evaluate DARA-IRDye800, an anti-CD38 antibody conjugated to an NIR fluorophore, for spatiotemporal imaging of CD38.
  • To assess the potential of DARA-IRDye800 as a contrast agent for preclinical MM research.

Main Methods:

  • Stability and binding affinity studies of DARA-IRDye800 with human serum and myeloma cells.
  • In vivo NIR fluorescence imaging of immunocompromised mice with intra- and extramedullary MM tumors.
  • Ex vivo biodistribution and flow cytometry to validate in vivo imaging findings.
  • Imaging of mice treated with therapeutic doses of daratumumab (DARA) to assess treatment response.

Main Results:

  • DARA-IRDye800 demonstrated stability and high affinity for CD38 (KD = 3.5 ± 0.05 nM).
  • Significant contrast enhancement (5- to 18-fold) was observed in tumor-bearing regions.
  • Therapeutic DARA treatment led to an 11-fold decrease in in vivo fluorescence intensity, indicating treatment response.

Conclusions:

  • DARA-IRDye800 is a valuable tool for preclinical evaluation of CD38 expression in MM.
  • This imaging approach enables spatiotemporal monitoring of myeloma engraftment and kinetics.
  • DARA-IRDye800 facilitates the investigation of anti-CD38 therapies in a preclinical setting.