Impact of Preprocedural Aortic Valve Calcification on Conduction Disturbances after Transfemoral Aortic Valve
Peter Stachon1, Johannes Steinfurt2, Tim van de Loo2
1University Heart Center Freiburg, Department of Cardiology and Angiology I, Faculty of Medicine, University of Freiburg, Freiburg, Germany, peter.stachon@universitaets-herzzentrum.de.
Insights
Calcification patterns on the aortic annulus increase the risk of conduction disturbances after transcatheter aortic valve replacement (TAVR). This risk is higher with balloon-expandable valves, impacting pacemaker needs.
Area of Science:
- Cardiology
- Interventional Cardiology
- Cardiac Imaging
Background:
- Transcatheter aortic valve replacement (TAVR) is a common procedure for aortic stenosis.
- Conduction disturbances, including atrioventricular block and pacemaker implantation, are known complications of TAVR.
- The role of pre-procedural aortic valve calcification patterns in these complications requires further elucidation.
Purpose of the Study:
- To investigate the impact of aortic valve calcification characteristics on conduction system disturbances following TAVR.
- To determine if specific calcification patterns are associated with increased risks of atrioventricular block, QRS prolongation, or permanent pacemaker implantation.
Main Methods:
- Retrospective analysis of 169 pre-procedural multislice computed tomography scans from transfemoral TAVR (TF-TAVR) patients.
- Quantitative measurement of aortic annulus and valvular calcification volume, distribution, and orientation.
- Statistical analysis using linear and logistic regression to correlate calcification patterns with postoperative conduction disturbances.
Main Results:
- Total calcification volume and distribution did not significantly impact conduction.
- Oval calcification of the left aortic cusp was linked to increased atrioventricular block degree.
- Orthogonal annular calcifications were associated with QRS prolongation and higher rates of permanent pacemaker implantation.
- These risks were significantly amplified in patients receiving balloon-expandable Edwards SAPIEN 3 valves.
Conclusions:
- Orthogonal calcification at the aortic annulus is an independent predictor of conduction disturbances post-TAVR.
- The risk of conduction disturbances is more pronounced with balloon-expandable valve implantation.
- Pre-procedural imaging assessment of calcification patterns may aid in risk stratification for TAVR patients.
Aim:
The present study analyzes in depth the impact of different calcification patterns on disturbances of the conduction system in transcatheter aortic valve replacement (TAVR) patients.
Methods And Results:
A total of 169 preprocedural TAVR multislice computed tomography scans from consecutive transfemoral (TF) TAVRs performed between 2014 and 2017 using either Edwards SAPIEN or Medtronic Evolut R valves were retrospectively evaluated. The volume, distribution, and orientation of annular and valvular aortic valve calcification were measured and their impact on postoperative conduction disturbances was determined using linear and logistic regression analyses. The total volume of calcification and distribution at the aortic annulus or valve did not influence the conduction system. Oval calcification of the left aortic cusp was independently associated with an elevated risk for an increase in atrioventricular block degree (+0.6, p = 0.03). Moreover, orthogonal calcifications at the level of the aortic annulus were associated with an increased risk for QRS prolongation (+26 ms, p = 0.004) and an increased risk for permanent pacemaker implantation (OR 4.3, p = 0.03) after TF TAVR. This was more pronounced in patients undergoing TF TAVR using a balloon-expandable Edwards SAPIEN 3 valve (QRS +38.195 ms, p < 0.001; OR permanent pacemaker 15.48, p = 0.013).
Conclusion:
Orthogonal annular calcification confers an increased risk for conduction disturbances after TAVR. This is even more pronounced after implantation of balloon-expandable valves.
More Related Videos
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation III: Medical Management
Aortic Regurgitation I: Introduction
Cardiac Catheterization I: Pre-Procedure Overview
Mitral Valve Prolapse II: Assessment and Management
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT