Related Experiment Video
Updated: Dec 8, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Ultimate Bearing Capacity Analysis of CFRP-Strengthened Shield Segments Using Bonding Slip Behavior Experiments
Hong-Bin Nie1,2, Shuan-Cheng Gu1
1School of Architecture and Civil Engineering, Xi'an University of Science and Technology, Xi'an 710054, China.
Abstract:
Shield segments of subway tunnels are often exposed to the combined actions of several hygrothermal factors that could lead to accidents such as water seepage and tunnel collapse. Further, they often break and deform owing to formation pressure. In addition, uncertainties related to the stress relaxation characteristics and bonding performance of carbon-fiber-reinforced plastics (CFRPs) under a hygrothermal environment make their application in subway systems difficult. This study analyzes the effects of the slip-on-bending strength of CFRP-strengthened shield segments in a hygrothermal environment. In the study, the shield segments are damaged at ambient pressure under a combination of humidity (0%, 5%, and 10%) and temperature (20 °C, 25 °C, 30 °C, and 40 °C). An experimental procedure is designed to evaluate a CFRP-reinforced concrete arch. The method predicts the load-slip relationship and maximum shearing stress and strain. Moreover, confined compression tests are conducted on a tunnel segment lining strengthened with CFRP to evaluate the bearing capacity of the CFRP-strengthened shield segments. An equation for the latter's ultimate bearing capacity is developed based on the elastic layer system theory, stress boundary condition, and bending stress characteristics of axisymmetric elements. It was found that the results from the developed model are compared with the experimental values of CFRP-strengthened shield segments under different humidity values (0%, 5%, and 10%) and a constant temperature. The ultimate strength-the debonding deflection of the CFRP-strengthened shield segment-can be predicted using the proposed ultimate bearing capacity equation with sufficient accuracy.
Related Concept Videos
Bearings: Problem Solving
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...
Stress Concentrations in Circular Shafts
Design of Transmission Shafts - Stress Analysis
Design Consideration
The factor of safety is another key...
Shearing Stresses in a Beam: Problem Solving

